279737 Whirlpool Dryer Load Timer

279737 Whirlpool ‍Dryer Load Timer is an ⁣electromechanical control assembly used in many Whirlpool dryers ⁣to sequence ‌and time drying ⁤cycles. As a rotary cam-driven‍ timer it contains ⁢a⁢ motor⁢ and a bank of switching contacts that⁢ close and open circuits ​at⁤ predetermined positions, providing timed control of ⁢the dryer’s functions rather than continuous manual ⁤switching.

Within ⁣the appliance the ⁤load‌ timer coordinates ⁤the interaction between the user-selected ‍cycle and the dryer’s primary⁣ systems: ⁢it supplies switched power to the drive motor, heating circuit‍ (element or gas valve/igniter), ‌and auxiliary controls such⁤ as thermostats, ⁣door ​switch ⁢interlocks, ⁤and timer-driven sensors. The timer’s‍ cams⁤ and contacts determine⁤ when heating is applied, when the drum motor runsand when ‍auxiliary loads‍ are energized, so failures or contact wear can⁣ produce mis-sequenced or non-functioning subsystems even‌ when individual components test good.

In this article you will find a technical​ description of ⁤how the 279737 timer ‍functions, guidance ⁢on model⁣ and​ connection compatibility,⁢ common‍ failure‍ symptoms to watch for (such⁣ as failure to advance, intermittent heatingor burned contacts),​ practical troubleshooting steps‌ including electrical checks and mechanical ‌inspectionand replacement considerations such as matching terminal layouts, ‍mounting ⁤orientationand⁣ safety precautions for working on mains-powered equipment. the intent​ is ⁢to provide a technician or experienced‍ appliance ‌owner with the diagnostic ‌criteria and ⁢procedural context needed to assess and, were ⁢appropriate,‌ replace the timer assembly.

Table of Contents

Function and Role of the Load​ Timer in Whirlpool‌ Dryer ​Cycle Control

The ‌ 279737 Whirlpool Dryer⁣ Load Timer is an⁣ electromechanical​ sequencing device that‍ directs​ line voltage to the dryer’s ⁢motor, heating element and⁤ accessory circuits by ‍means of a cam-operated contact ‌stack. As the timer ⁤motor advances the cams, specific contacts close ⁢or open to implement ​user-selected program steps (tumble, heat, cool-downand ‌stop); the timer therefore performs⁢ power ⁣routing and cycle sequencing rather than ‍sensing‍ temperature. Replacements must match⁤ the part number,⁤ terminal layout and harness ⁤connectors so the cam profiles and contact assignments align with the dryer’s ⁣wiring diagram and electrical ratings.

  • Primary functions: sequence power to⁤ motor and​ heater,⁣ provide ‍timed ​transitions⁣ between ‌cycle‌ phases, ⁢and terminate power at the end of a⁢ cycle.
  • Common failures/symptoms: timer ‌motor dead ​or slow, contacts burned ⁤or intermittent, dryer runs but will not ⁤heator cycles do not advance.
  • Practical checks: verify incoming‍ line voltage at the ⁤timer⁢ common, observe ⁤voltage at heater and motor terminals ⁤during expected phases, test timer motor continuity ⁣and listen‍ for the timer drive, ⁣and compare contact behavior to the service wiring diagram.

For⁤ troubleshooting, technicians ⁤typically ‌start by ‌confirming mains ⁢presence at the‌ timer‍ input ⁣and ⁢then exercise the ‌timer⁣ to observe which outputs are⁣ energized ⁢at each cam ⁤position; ⁤a simple multimeter check of continuity ⁤across expected⁤ closed contacts while ‍advancing⁣ the timer identifies mechanical contact faults. In some modern ​models ​the mechanical timer ⁣has been superseded by electronic control modules, so ‍verify model compatibility‍ and terminal mapping before installing​ a⁣ replacement: matching ⁣the​ 279737 Whirlpool Dryer Load⁤ Timer to the dryer’s service sheet prevents miswired ⁤circuits and‌ unexpected behavior.

Item Description
Timer motor Drives the cam ⁣stack to advance contact positions (commonly 120⁣ VAC)
Common ⁤(line) Incoming line-voltage feed distributed to contact banks
Heater ⁣contact Switches ⁢power to the heating element during heat phases
Motor contact supplies the ‌drum motor/tumble circuit when closed

How​ the 279737 ⁤Whirlpool⁣ Dryer Load Timer‍ Works inside the Appliance: Electrical‌ Pathways and Mechanical⁢ Sequencing

The 279737 Whirlpool Dryer‍ Load Timer is an electromechanical sequencing device that routes incoming‍ mains voltage⁢ through‍ a stack of cam-operated ⁢contacts to control⁤ the motor, ​heating circuitand timed functions.⁣ Internally it contains a ⁣small synchronous drive ​motor and a cam assembly; as the⁤ drive⁢ advances, individual contacts ⁢close​ or ⁢open‌ according​ to the selected cycle.​ The timer⁢ does not generate temperature control on its ⁤own⁤ but⁣ provides switching points‌ for thermostats, the motor, start/door switchesand the heating element, so worn or pitted timer⁣ contacts⁤ can⁤ produce symptoms such as failure to advance, intermittent heator inability ⁤to select ‍certain cycle steps. In practical replacement work ‌you must match ‌the‍ terminal‍ layout ⁣and cam function to the​ dryer model-electromechanical timers are not interchangeable with electronic control boards that use ‍sensor-driven logic.

  • Common⁣ symptoms ⁤tied to timer faults: ‌failure to advance, no heat while​ motor runs, stuck on⁣ one cycleor‌ erratic cycle switching.
  • Key behaviors: timer advances only when the motor circuit is​ energized on ⁣many models; heat circuit‌ is routed​ through thermostats and the timer’s heat ⁤contacts.
Item Description
Timer drive motor Provides rotational motion to the cam stack; ​typically powered only when the dryer​ is running.
Cam-operated contacts Switch ​mains voltage to ⁣motor, heating elementand auxiliary circuits at programmed intervals.
Heat circuit path Line → timer heat contact​ → thermostats/thermal fuse‌ → heating element ⁤→ neutral.
motor/advance path Line → ‌start/door⁤ switch → motor → timer drive; motor operation commonly enables timer advancement.

Understanding the⁣ electrical pathways helps with⁤ targeted⁤ troubleshooting: measure for 120 VAC at the timer’s common ​terminal and at individual cam outputs ​while the dryer⁤ is in a given cycle to verify that the timer is‌ supplying ​power ⁣to the motor⁢ and heat circuits. Such as, ⁤if the motor receives voltage but the element does not, ‌the technician ⁢should inspect the timer’s heat contacts and ⁢series ⁢thermostats⁤ or fuses; if the timer ‌fails to advance ‌despite the motor⁢ running, the internal ⁤drive motor ​or ⁤the​ cam coupling may​ be worn. When replacing the timer,confirm mechanical sequencing ⁣(which‌ contact‌ closes ​at each position) and terminal numbering against the ⁤dryer wiring diagram-mis-matched ⁣sequencing ​will produce incorrect cycle behavior even if terminals physically fit.⁤ Always disconnect mains ​power before probing or replacing the timer and use‌ the ⁣dryer’s schematic to trace ‍control paths rather than relying on pin⁤ position alone.

The 279737 Whirlpool‍ Dryer Load Timer⁤ is ‌an electromechanical ‍control that ⁣sequences power to the ⁣motor, heating elementand‍ ancillary‌ circuits by switching cam-operated ⁢contacts as ⁤the timer motor advances.⁤ In practical ‍terms, the timer routes 120 VAC to different circuits ⁤according‍ to the selected⁤ cycle and remaining run ‌time; when the cam contacts ⁢or the timer motor degrade the dryer can ‍exhibit mis-sequencing ​(for example drive⁣ motor power without heat or heat continuously applied). ⁤Technicians should verify ‌physical ⁢compatibility by matching connector harnesses, mounting‌ pointsand terminal markings to the ⁤service schematic for the ‌specific Whirlpool model before replacing⁤ the assembly.

  • No advancement‍ of cycle or stuck⁢ in one cycle position ⁤while the⁣ drum turns‍ (timer motor not advancing).
  • Continuous or no heat while ⁣other‌ functions operate normally (contacts⁢ shorted or open ‌in the heater ‍circuit).
  • Intermittent‍ operation,skipped cycle⁣ steps,or audible grinding/clicking​ from the timer ⁢(worn cams or debris ‌in mechanism).
  • Visible burning, pittingor melted terminals⁣ at the⁤ timer indicating high-resistance⁤ contact⁣ failure.

Diagnosing⁢ timer-related faults focuses on verifying the timer motor supply and the‌ state of the switch contacts ⁤across ⁢cycle positions. Use ​a voltmeter to confirm the timer motor ‌receives ​approximately 120 VAC when the dryer ‌should advance; ⁤lack of​ voltage can indicate upstream failures (door switch,thermal⁣ cutouts,or selector switch)⁤ rather than the ⁣timer motor⁣ itself.⁣ With the timer‍ removed‍ or back-probed per the wiring diagram,⁣ check continuity between the common and position-specific ​terminals for several⁤ discrete timer positions-the contacts should show ​low resistance when closed and open when not selected. If contact ⁢continuity is inconsistent with the schematicor if the ⁣timer ‍motor ⁢shows an open⁢ winding or draws ‍excessive current while⁤ not turning, replace the 279737 timer assembly;​ cleaning ⁢pitted contacts is a temporary measure‌ but⁢ does not restore precise cam timing.

Item Description
Timer motor ⁣supply Approximately 120 VAC present during ⁤advance; ‍absence⁤ suggests upstream⁢ circuit fault.
Contact⁣ continuity Low resistance ​when contact ⁤is engaged for the given timer position; open⁤ when disengaged-compare to model schematic.

Compatibility, Replacement Considerations, Step-by-Step⁤ Installation‌ and Troubleshooting⁢ Procedures

The 279737 Whirlpool Dryer Load⁣ Timer is an‌ electromechanical timer assembly ​that sequences‌ dryer⁣ cycles by using a small synchronous‌ motor⁣ and⁣ cam-operated switch​ contacts to route power to the heating element, motor,​ and other control circuits. ‍Functionally, ⁤the timer advances ⁣the program stages ⁢(timed ⁤dry, cool ⁣down, automatic‌ moisture‌ control) and provides ⁢switching points​ for thermostats and safety interlocks; technicians should confirm the replacement timer ⁣has the same terminal layout, shaft orientation, mounting flangeand motor voltage (typically‍ 120 VAC)​ as the original to ensure⁢ electrical‍ and mechanical compatibility.When assessing compatibility, compare⁣ the physical connector arrangement ​and ⁤cam‌ profile against the⁣ service schematic rather than​ relying solely on model name-two timers that ‌look similar can have different contact ⁣arrangements that ⁣change circuit ‍behavior under load.

For replacement and troubleshooting, begin ​by⁢ taking clear photos ‍of the ⁤existing wiring and ‍control positions, ⁤then​ disconnect power and label each‍ terminal before removal; after ‍swapping⁤ the⁤ timer, verify proper ⁤operation by running a manual‍ cycle and measuring for continuity or correct voltage⁣ at the expected contact points. Typical installation and diagnostic workflow⁤ includes steps to remove access panels, ⁣unfasten the timer, match and attach the harness, ⁢and ⁤verify that the motor advances the cam; if⁣ symptoms persist (timer does not advance, dryer stalls‍ mid-cycleor cycles are erratic),⁣ use a multimeter ⁢to⁣ check ⁣for⁣ 120 VAC at​ the timer motor, continuity⁤ through the cam contacts during expected positionsand‍ proper operation of⁤ interlocks ⁣such as door and‍ belt switches.

  • Key replacement steps: power off, document wiring, ‍remove screws, swap unit, reconnect labeled wires,‍ power on‌ and run‍ diagnostic⁢ cycle.
  • Troubleshooting checks: measure supply voltage to⁤ timer motor, continuity ‍of cam ​contacts in each cycle positionand verify mechanical rotation (motor ​audible/humming).
Item Description
Model 279737 Whirlpool‌ Dryer Load Timer‍ – replace only⁢ with matching terminal/cam configuration
Voltage Timer motor‌ typically operates⁢ on⁢ 120 VAC; confirm ⁣with⁢ schematic or meter before replacement
Compatibility Matches dryers with identical mounting flange, shaft lengthand‌ connector ⁤arrangement; cross-check part ⁣numbers and ⁢wiring diagrams

Q&A

What is the⁢ 279737 Whirlpool dryer load timer ⁢and what does ​it do?

The 279737 is ‌a dryer cycle/load timer assembly ‌used ​on some ​whirlpool-family dryers. ⁤It mechanically (or‌ electromechanically) sequences the dryer’s ⁢circuits during‍ a selected cycle, routing power ​to the motor, heaterand other control switches⁢ at the correct times‍ so ‌the⁣ dryer advances through timed and⁣ automatic portions of a ⁣cycle.

What are ‍common ‍symptoms ​that ‍the 279737‍ timer is​ failing?

Common signs include: the dryer won’t advance through ‌cycle settings (stuck on one position), no​ power to ⁣the heater ‌or ⁢motor ‍during⁤ portions of the cycle, the timer⁤ knob⁣ won’t turn,​ or intermittent‌ operation where some‌ functions work sporadically. Note that similar‍ symptoms⁢ can be caused by other⁣ parts⁤ (door switch, thermal ⁤fuse, cycling thermostat,‍ wiring), ⁢so diagnosis is important.

How can ​I​ test the 279737 timer to see if it’s⁣ defective?

Always unplug the dryer before testing. Use a multimeter to check continuity across the timer’s switch ‌contacts as you manually advance the timer ‌knob‍ (or ⁢energize the timer⁤ motor) and compare to the dryer’s wiring diagram/service sheet‌ to know ‍which contacts⁣ should ‌be ⁢closed in each cam position. Also⁤ check for ⁢continuity ​in the timer motor windings. If the ​expected contacts⁢ do not ⁣open/closeor the timer motor has infinite resistance (open), the ⁤timer is likely ⁣defective. ⁣If unsure about reading the wiring ⁤diagram or live-voltage checks,⁢ consult a service technician.

How do I replace the​ 279737 ​timer? Is it ⁤a job I can do myself?

Replacement ⁤is typically straightforward for ‍a person comfortable with basic‍ appliance repair: unplug⁢ the dryer, remove⁤ the control ‍panel or back cover to access the timer,‍ take‌ a photo or label each ⁣wire, pull off⁣ connector ‍terminals, remove ⁣mounting ​screws, install the⁤ new⁤ timer, reconnect wires in‍ the correct​ positions, reassembleand test. Use ⁤care to align the timer shaft/knob correctly. If you are not comfortable‌ working with electrical parts or removing panels, hire a‌ qualified technician.

Are‍ there any safety steps⁢ I should follow ⁤before ‌working on the timer?

Yes. Disconnect power‌ at the wall outlet (unplug) before doing⁣ any work. If you must test live⁣ circuits, use insulated tools ⁤and ⁣a ‍properly rated multimeter⁤ and‍ be experienced with⁣ live-voltage⁣ measurements. Avoid working on the dryer with wet hands​ or in damp conditions. ⁣Also ensure the gas supply is ​turned off if working ⁤on‍ a gas dryer and⁢ follow manufacturer safety ‌guidelines.

How do ⁢I know ‍if⁢ the 279737​ is the correct replacement for my dryer?

Verify compatibility ‌by matching ‌the‍ original part number on the old timer ‌and​ checking ‌your ⁤dryer’s model and​ serial number against the manufacturer parts list or an authorized parts‍ supplier. Do‍ not ‍rely solely⁢ on⁤ visual similarity-use ‍Whirlpool’s⁢ parts lookup or an official⁤ parts diagram ​to confirm the‍ 279737 is listed for your specific dryer model.

Can⁢ the⁣ 279737 timer be repairedor‌ should it be replaced?

Most technicians will replace a faulty⁤ cycle timer rather​ than repair it. Mechanical wear, burned⁤ contacts ⁤or a⁣ failed timer motor are‍ common⁣ failure ‌modes and replacement is usually‌ faster, ‌more reliable and cost-effective ​than attempting an internal repair.In rare cases​ a technician​ might potentially ⁢be⁣ able‌ to clean or re-seat​ contacts,‌ but that is not ‌a guaranteed long-term fix.

What might cause ⁢the timer to fail prematurely and how can ‌I prevent it?

Causes include arcing/burned contacts‌ from⁢ high current draw, overheating⁢ due to⁣ blocked​ vents or a failing‍ cycling thermostat, moisture ​ingressor​ simply⁢ mechanical wear from⁤ heavy use. Preventive actions: keep ​dryer vents and‍ lint⁢ traps clean‌ to avoid overheating, have thermostats and thermal fuses checked during maintenance,⁤ and avoid overloading the⁢ dryer. ‍Regular maintenance⁢ and prompt ‍repair of related failures reduce stress on the timer.

Wrapping Up

The‌ 279737 Whirlpool dryer load timer is‌ a ⁣key ‍control ⁤component ‌that ‌governs cycle ⁢sequencing and‍ timing within⁤ compatible‍ Whirlpool⁣ dryer models. ⁤By coordinating when the⁤ motor, ⁢heating elementand various‌ switches‍ are energized,⁤ the load timer helps ensure dryers complete ‍selected cycles‌ reliably and safely. Its proper function contributes directly to consistent drying performance and efficient appliance operation.

because⁢ symptoms of ⁤a⁣ failing load timer-such ‍as cycles that​ do not advance, inconsistent heating,‍ or ⁣intermittent operation-can overlap with other electrical or mechanical ‌issues, accurate diagnosis is ‌essential. Confirming the timer⁢ as the root cause before replacement helps⁣ avoid needless parts ‌changes and ensures the underlying issue is ⁢addressed. ⁣When replacement is ‌required, using the correct part number ​and following‌ manufacturer-recommended ‌procedures​ preserves appliance safety and⁢ reliability.

the 279737 load timer plays⁤ an important role in dryer operationand prompt, accurate identification and ‍replacement of a defective timer ⁤can restore normal function and extend the appliance’s service life. ​For complex​ diagnostics or repairs, consult the dryer’s service documentation or⁤ a qualified service ⁢technician to ⁤ensure ​the repair ⁢is performed safely and effectively.


Professional Appliance Service

If your appliance requires professional diagnosis or repair, visit

Revolff Home Services
for expert appliance repair services.

For local appliance service information see

Dryer repair Henderson
.

Replacement parts for many appliance models can also be found at

Reliable-Parts-Hub
.

Recommended Products