297237702 Frigidaire Refrigerator Start Relay

297237702 Frigidaire‍ Refrigerator ⁤Start Relay is a compressor start relay used on⁣ single‑phase refrigerator⁣ and freezer compressors; it is an electrical ‌switching device designed⁤ to momentarily engage the compressor’s start circuit so the ‌motor can reach running speed. As a component it typically mounts at or near the compressor or inside the refrigerator’s control compartment, ⁢and it performs the transient switching function that supplements the run winding (or start capacitor ​where applicable) during motor ‍startup.

Inside the‍ appliance the start relay interacts directly with⁣ the compressor⁣ motor’s start and run windings, the thermal overload protectorand the refrigerator’s control/thermostat wiring. When the control calls‍ for ⁢cooling the relay provides a‍ timed or current‑sensing⁣ connection to the start⁢ winding‌ (or modifies circuit impedance ⁢in the case of solid‑state designs)⁤ and then opens once the motor is up to speed; this behavior prevents sustained​ high​ current⁢ thru the start circuit and protects the compressor. Correct relay function is therefore integral to proper⁣ compressor starting torque, normal starting⁢ current, ⁢and long‑term motor protectionand it affects diagnostics when a⁢ unit​ fails to start, humsor cycles abnormally.

in this article readers will find a technical explanation ‌of ​the ⁣relay’s function and variants, guidance on compatibility and ⁢identification for Frigidaire models, common ⁤failure modes and symptoms to expect, key diagnostic⁣ checks a technician or learned owner can perform with basic toolsand practical considerations for⁤ safe replacement and correct part selection. ⁢The discussion emphasizes⁣ electrical and‍ mechanical interactions with the ⁤compressor and related protective devicesand highlights the specification and installation points that determine weather a replacement ‌part will restore reliable operation.

Table of‌ Contents

Function ⁢and role of the start relay ⁣in Frigidaire refrigeration compressor⁤ operation

The 297237702 frigidaire ​Refrigerator Start Relay provides ‍the brief high-torque connection required to spin a hermetic compressor from standstill. on⁤ energization the relay momentarily⁤ connects​ the start winding (or its equivalent⁤ PTC element) to the ‌supply ⁤so the rotor ‌overcomes static friction​ and begins to accelerate; once the compressor reaches running speed the ​relay interrupts that connection⁤ so the motor runs⁤ on the run⁤ winding only.In‍ practical systems‌ this relay is coordinated ⁣with an overload protector and is chosen ⁤to match⁢ the compressor’s locked-rotor torque and rated starting current; mismatched coil ‌voltage, ​contact ratingsor pinout can prevent start or cause nuisance tripping even ​if the compressor itself⁢ is healthy.

  • Humming compressor with no ‌spin (start winding not⁣ engaged)
  • Repeated click ⁤or relay chatter on power-up
  • Intermittent starts​ or extended crank time
  • Tripped breaker or⁢ blown overload at startup
Item Description
Start terminal Provides the temporary connection to the start winding or PTC element during ⁢spin-up
Run terminal Continuous connection​ to ​the run winding​ while compressor is operating
Common/Line Supply feed and physical connector that interfaces with compressor terminal block

Compatibility ⁢and replacement require matching electrical ratings and ⁢physical interface: ‍verify coil voltage, maximum ⁤current rating, terminal layout ⁣and ‌whether‌ the ​relay integrates⁤ an overload or mounts separately to the compressor. Technicians typically confirm relay operation⁤ by observing ‍audible engagement, measuring ⁤continuity between⁤ start/run terminalsand monitoring inrush current against the compressor’s specifications; absence of a transient connection, a permanently⁣ closed ⁣contactor a‍ failing PTC will produce the‌ symptoms listed above. Replacing a failed relay with a correctly specified 297237702 or an ​equivalent‌ that meets the same ratings restores correct start sequencing and reduces ​stress on the⁢ compressor and control circuitry.

How ⁣the ⁤297237702 Frigidaire refrigerator Start Relay operates within ⁢the compressor start circuit

The 297237702 Frigidaire Refrigerator​ Start Relay is a small⁣ but⁢ critical component in⁤ the⁣ compressor start ⁤circuit ⁤that momentarily connects the⁢ compressor’s start winding to the supply to produce the extra torque required ⁣at spin-up. In​ practice ⁢this‍ relay sits ‍on or near the‍ compressor terminals and‍ is selected to match the compressor’s starting current⁢ and voltage characteristics; its correct electrical and thermal behavior determines⁣ whether the hermetic ⁢motor receives a short-duration start boost without overheating. Technicians should treat this part as a direct functional replacement ​only ​if ​its terminal configuration and electrical ratings match the original, because an incorrect relay can ⁢permit excessive inrush, fail to disconnect the start ⁤windingor ​shorten compressor life.

During a ⁢start⁢ cycle the⁣ relay closes the start path only long enough for the compressor ​to reach operating speed,then opens to remove the start‍ winding from the ‍circuit; common ⁤implementations include a current-sensing‌ (mechanical or electronic) relay or a PTC-type device​ that increases ⁣resistance as it warms. Typical operational behaviors and ⁤failure⁤ modes are straightforward to diagnose: ⁤a sticking or welded relay⁣ can keep the start winding ‍energized and cause overheating, a‍ failed open ⁢relay prevents starting and results in humming and repeated attemptsand intermittent contact produces hard ‌starting ​or ⁤frequent cycling. Practical checks include listening for the‌ characteristic click at start,⁣ measuring ‍continuity between the ⁣compressor terminalsand‍ verifying the relay’s compatibility ⁢with the compressor’s start and run ratings.

  • Momentary start-winding engagement to provide starting torque
  • Sensing/disconnect​ method: PTC, current-sensingor electronic timing
  • Failure symptoms: humming, no start, repeated attempts, overheating
Item Description
Terminals C (common), S (start), R (run) – interface​ with compressor pins
Function Provides a brief connection of the start winding during motor ‍spin-up, then disconnects

Diagnostic indicators and common ⁢failure symptoms of ⁤a defective start relay

The⁤ 297237702 Frigidaire Refrigerator ⁢Start‍ Relay is the electromechanical ​or solid‑state device‌ that momentarily applies power to the ​compressor’s⁢ start winding‌ to produce the initial torque necessary for startup, then isolates that winding once the compressor‌ reaches running speed.Physically ‍and electrically the relay must match ‌the compressor’s terminal arrangement‌ and the refrigerator’s mounting and​ overload protection scheme; substitutions should be verified against compressor model numbers and terminal labeling rather than assumed interchangeable. Relay failures typically alter‌ normal start behavior rather than the ⁢refrigeration circuit itself, so understanding whether a relay ⁢is ​PTC/solid‑state, a centrifugal typeor ‍an integrated ⁣relay/overload assembly helps determine compatible replacements‍ and appropriate test‌ methods.

Technically useful diagnostic‍ indicators combine audible, electrical and visual cues: repeated‍ clicking⁣ at the relay,⁣ a continuous humming compressor that never starts, frequent thermal⁢ trips‍ or blown fuses, ⁤and visible⁣ overheating or scorching on the relay body suggest relay malfunction. ‌Practical field⁤ checks include a visual​ inspection for heat damage, a continuity/insulation test of terminalsand⁤ a functional swap with a ⁢verified compatible⁢ unit;⁣ disconnect ‌power before probing or replacing the relay. For ambiguous cases, monitoring ⁢compressor current⁣ draw ​during attempted⁣ starts or using a known‑good relay to⁢ compare behavior provides⁤ confirmatory evidence without relying solely​ on measurements ​that vary by compressor ⁣design.

  • Repeated clicking while ‌compressor⁣ fails to start
  • Compressor hums but does not engage to‌ run
  • Intermittent starts or stops, followed by normal operation
  • Relay housing is hot,‌ meltedor shows burn marks
  • Frequent thermal trips ‍or tripped circuit breakers⁤ during start attempts
Item Description
Function Applies ‍then removes⁣ power to the‌ compressor ​start ‍winding to enable‌ motor startup
Compatibility Must match compressor terminal configuration and mounting; verify ⁤against compressor‍ model or service manual
Basic diagnostic⁤ test Visual inspection, ⁢audible behavior during start, continuity checks, ⁢and ⁣controlled swap with a known‑good relay

Compatibility, replacement ​and ⁣installation considerations for 297237702 and equivalent Frigidaire start relays

The 297237702 Frigidaire Refrigerator Start Relay is​ a​ start-assist device that momentarily connects the compressor’s start ⁣winding during ⁢motor start-up and⁢ then removes that connection once the motor reaches ‌running speed. It may be implemented as a PTC⁤ element,a ​current-sensing relay,or a solid-state module depending on the OEM ‌revision; ⁢the critical characteristic is the‌ timing and current-handling⁢ behavior required by the ‌compressor. ⁢When⁤ evaluating⁢ compatibility, match​ the relay’s electrical⁣ ratings (line voltage, inrush/current limit), terminal layoutand​ whether the assembly includes an integrated thermal overload-substituting ‌a relay without ⁢the correct trip characteristics or missing overload protection can allow excessive locked-rotor ⁣current or fail to disengage the‌ start winding, producing humming, high amperage or shortened compressor life.

  • Verify compressor⁣ type and ‌rating (PSC, permanent-split⁣ capacitorand ‌nameplate locked-rotor‌ amps).
  • Confirm‌ relay type (PTC vs. ‍current-sensing) and physical terminal/harness compatibility.
  • Check for integrated⁤ overload versus separate overload required by the system.
  • perform pre-replacement tests: ⁤measure start/run winding resistance and check ‍relay continuity or switching behavior with a ​controlled ‌bench test.

Installation considerations include proper ⁣electrical isolation, secure terminal ⁤connectionsand⁤ correct mounting orientation to maintain heat‍ dissipation and mechanical strain ⁣relief; loose ⁤terminals or poor thermal contact change the‌ relay’s operating ⁢temperature ⁣and can alter trip behavior.If the existing relay contains⁣ the overload, replace with an assembly that duplicates that protection or install an appropriate external overload; for exmaple, replacing a combined relay/overload​ with a‌ relay-only⁤ aftermarket⁢ part‌ will require fitting a separate thermal protector sized to the ⁤compressor’s locked-rotor current. ‌After replacement, verify normal start ⁢current and that‌ the⁤ relay drops ⁤out‌ within⁤ the expected‍ time frame during no-load bench runs before reassembling the ‌cabinet.

Item Description
Part ‍/ Type 297237702​ (start⁣ relay; PTC/current-sensing variants⁣ exist)
Function Connects start winding during motor start and disengages when running
Key checks voltage⁢ rating, inrush/current spec, ‌terminal layout, presence of‌ thermal overload

Q&A

What is the function of the 297237702 Frigidaire refrigerator start relay?

The 297237702 start relay is a small ‍electromechanical⁢ or solid-state device that helps the compressor start. It temporarily⁣ connects⁢ the compressor’s start winding (or provides the extra starting torque in electronic systems) for a‍ short time and then disconnects it once the compressor is running. Without a working start ⁣relay the ⁤compressor may hum, click, ​or fail to start, causing the refrigerator not to cool.

What ⁤are the common ‌symptoms of a bad​ 297237702 start ‍relay?

Common symptoms ‍include: compressor humming or buzzing but not starting, repeated clicking or tripping of the circuit breaker, the refrigerator not cooling (or cooling intermittently)and sometimes visible ‌burn marks, meltingor a ‌burnt ⁤smell near the relay.‌ These ‌symptoms‍ can mimic other problems,⁣ so ​the relay should be tested before⁣ replacing the‌ compressor.

How do ‍I‍ safely test the 297237702 start relay?

Turn power ​to the refrigerator off​ at‍ the wall and unplug it.Access the relay by pulling the ⁣fridge ‌away and removing the small cover over the compressor terminal area.Inspect the relay for obvious ⁢damage. Use a multimeter to check for continuity and compare ‍readings to the manufacturer’s spec or a known-good ⁢unit. If the relay is open where ​it should show continuity, shortedor shows‍ continuity⁢ to ground, ‌it should be replaced. If you are not⁢ comfortable doing this or lack​ the ‍correct specifications, have a ⁣qualified appliance technician perform the test.

Can ⁣I install the 297237702 myself,‌ and what are the basic replacement steps?

Replacing the relay ‍is a common DIY job for someone comfortable working on appliances: unplug the ⁢unit, move it to access the back, remove the protective compressor terminal cover, pull off the old relay/overload module (they often pull straight off the compressor ​terminals or are held by ‍a clip), install the ⁤new 297237702 in the same orientation, replace the coverand restore power.⁤ Use basic hand tools and take safety precautions (unplugging and keeping​ fingers ​clear‍ of sharp sheet ⁣metal).If you are unsure, hire a technician.

Is 297237702 the correct part for my Frigidaire/Kenmore model?

Compatibility depends on the refrigerator model. 297237702 is⁣ used on a range⁣ of Frigidaire/associated-brand refrigerators but not ⁣all models use the same relay.​ Always ​check ‍your refrigerator’s model number and use the manufacturer’s parts lookup or a reputable parts supplier to confirm compatibility.​ Do not rely solely on ⁣photos-verify part numbers and model cross-references before buying.

How ‌much ​does the 297237702 start relay cost and where can ‍I buy it?

Price varies ⁢but typical ⁣cost for an OEM start relay is generally modest (often ​in‍ the $10-$50‍ range depending​ on supplier and whether it’s ⁢OEM or aftermarket). Buy from frigidaire-authorized parts dealers,major appliance‍ parts websites,local appliance parts stores,or authorized service centers⁤ to ensure you get the correct part and any applicable ​warranty. Avoid questionable sellers if exact compatibility isn’t ⁢listed.

If replacing ⁣the 297237702 doesn’t fix the problem, what else should I check?

If ‌the refrigerator still won’t cool after replacing the start relay, ⁣check the compressor itself​ (it could be seized ⁢or have‌ internal​ faults), the overload/protector, start capacitor ⁢(on systems that ⁢use one), the‌ evaporator fan, thermostat/temperature control, defrost⁤ systemand the sealed‍ refrigerant system for leaks. A technician can perform a full ‍diagnosis (including current draw tests and pressure ‌checks) to determine‍ if the compressor or sealed system requires repair.

Are⁤ there any ‌safety precautions or special notes when working ‌with the 297237702 relay?

Always disconnect power before accessing the⁤ compressor or relay ⁣area. Do not run the compressor by⁣ jumping or jury-rigging start​ circuits; ⁣that can damage the compressor. Avoid ⁣touching other components while the unit‌ is powered. If you encounter refrigerant leaks, oil on the compressoror suspect a‌ sealed-system ⁤failure, stop and call‍ a certified appliance technician-sealed-system repairs ‍require special tools‌ and refrigerant handling certification.

Insights and Conclusions

The 297237702 Frigidaire refrigerator start relay is a small but critical component that helps initiate compressor operation and ensures reliable cooling performance.By briefly energizing the compressor motor during startup and then disengaging, the start relay ⁣reduces stress on the compressor⁣ and supports efficient ⁣refrigerator cycling.When operating correctly, it contributes to‍ consistent temperature control and prolongs the life of ⁢the compressor and overall appliance.

Because start relay failure can‌ cause⁣ symptoms such as a refrigerator that​ does not cool,‍ unusual humming or clicking noisesor repeated ​compressor startup attempts, accurate‍ diagnosis is ​essential. Proper diagnosis-using visual inspection, basic electrical testingand confirmation of ⁣compressor behavior-helps distinguish a ‌faulty relay from other potential causes such as​ a bad‌ capacitor, thermostator compressor. addressing the specific root cause prevents unnecessary parts replacement and reduces repair ‍time and cost.

When replacement ​is required, ​installing the ⁣correct‍ 297237702 relay and⁤ following ‍manufacturer guidelines or⁣ using a qualified ‌technician will restore reliable operation and maintain safety. ‌Careful‍ installation, correct wiringand post-repair testing help ensure the refrigerator returns to normal performance. Routine maintainance and​ prompt attention to early symptoms further‍ reduce the⁣ risk of more extensive ⁣compressor ⁤damage and extend ‌the service life of the appliance.


Professional Appliance Service