137108000 Frigidaire Water Drain Pump and Motor Assembly

137108000 Frigidaire Water Drain​ Pump and Motor Assembly is an electromechanical drain pump⁢ unit designed to remove wastewater from laundry and similar household appliances. The‌ assembly typically combines ⁢a small ‍AC or DC electric ‍motor with an ⁢impeller housing, mounting flange and electrical connector to provide a compact, serviceable⁤ pump that can be attached to the appliance ⁤chassis and coupled to the drain⁤ hose.

Inside the ⁤appliance the drain pump evacuates water from the tub or sump during drain and spin ⁣cycles and works against the head ‍pressure of the drain plumbing. It ⁣is a point ‍of interaction ‌between the hydraulic path (tub, ⁤sump, filter, drain hose) and the‌ appliance control system: ⁣the pump receives a drive signal from the control board, may be monitored‍ indirectly ‍by water-level sensors or ⁣pressure switches, and⁣ must be⁣ mechanically sealed and mounted to prevent leaks and vibration. Proper electrical supply, sealing, correct hose routing and backflow ‌prevention are‍ all meaningful⁢ factors in its ​reliable ‍operation.

In this article you‌ will learn ⁢how the 137108000 frigidaire Water Drain pump and Motor ⁣Assembly functions, how to verify compatibility with appliance models and electrical specifications, common failure symptoms to watch for (for example no-drain, continuous⁣ hum, leaks or overheating),​ systematic troubleshooting steps⁤ to isolate electrical, mechanical or⁤ plumbing causes, and practical considerations when​ replacing the unit ‌such as verifying mounting orientation, connector type, sealing/gasket condition⁢ and​ OEM part-number matching. The goal is to give technicians, engineers and⁤ appliance ⁣owners clear technical context for diagnosing⁢ and servicing this component safely and ‍effectively.

Table of Contents

Function ⁤and Role of the Drain Pump⁤ and Motor:⁣ Hydraulic Flow, Debris Management, and Electrical ⁣Interface

The 137108000 Frigidaire Water Drain Pump and Motor Assembly pairs a small⁤ electric motor with a molded pump housing and impeller‍ to evacuate condensate and defrost water from the refrigerator’s ​drip⁢ tray to the external drain or evaporator pan.Fluid enters ⁤the housing through a screened​ inlet, is accelerated by⁤ the impeller, and is discharged through a short outlet ⁤hose; ⁣this hydraulic path is intentionally compact ⁣to ⁢fit under‌ the evaporator⁢ compartment while maintaining sufficient​ head to lift water past plumbing turns. In service this assembly is energized by the appliance‌ control during ⁤defrost and heavy-cycling conditions, and it must be matched to the ​refrigerator model for proper mounting, connector pinout, and flow orientation-verify appliance‍ model numbers and harness compatibility before replacement.

Debris management is achieved with an⁣ inlet screen and ⁤limited ⁤impeller‍ clearance; lint,scale,or broken ​glass can increase hydraulic drag and motor current,producing audible strain or thermal cutouts. The electrical interface is typically a small multi-pin plug that provides‍ switched supply from‍ the control board and may include a common return ‍or ground; diagnosing failures involves checking for presence ⁤of ‍voltage ‌at ⁣the connector during the drain event, measuring motor ⁢current for abnormal draw, and inspecting the impeller and inlet for obstructions. Common field observations,maintenance‌ actions,and inspection points‍ are summarized below.

  • Symptoms of hydraulic or motor ‌issues: slow/no drain, continuous run, noisy bearings, tripped thermal protection.
  • Maintenance steps:⁢ clear inlet screen, remove visible debris ⁣from ⁣impeller, confirm proper​ hose​ routing and ‌absence of kinks.
  • diagnostic checks: voltage at plug during pump operation, motor resistance/continuity, and impeller ‍free-spin test.
Item Description
Flow path Screened inlet​ → impeller → short discharge hose;⁣ compact design for low⁣ head lift applications.
Electrical interface Small multi-pin connector; switched supply from control board, perform‌ live-voltage check during drain cycle.
Failure modes Clogged inlet, ‌damaged impeller, motor ⁢winding​ failure, or connector/wiring faults causing intermittent operation.

How the 137108000 Frigidaire ‍Water Drain Pump and Motor Assembly Works Inside the Appliance: Mechanical ‌Operation ⁤and ⁣Control Integration

The 137108000 Frigidaire⁢ Water Drain Pump‌ and ⁤Motor assembly is​ a compact centrifugal pump and motor module mounted‌ at the base of the appliance that evacuates wash water through the drain hose during drain cycles. Mechanically, the ⁤assembly couples ⁤a small sealed motor to an axial/centrifugal impeller that pulls water through the tub strainer and pushes it out of the housing; the motor casing and seals⁣ protect the windings from splash and⁣ detergent exposure, while a molded mounting flange and electrical connector provide repeatable placement and⁤ serviceability. The pump typically includes an integrated impeller chamber ​and⁢ outlet port‍ designed to ​mate with the OEM drain hose ⁣and may incorporate‌ a simple check⁤ feature or molded⁢ path to⁤ reduce backflow; when replacing or troubleshooting, match the assembly part number and connector/mount orientation to ensure proper fit and⁣ hydraulic alignment with the appliance plumbing.

From a control viewpoint, the motor is switched by the appliance control board (usually via a relay or⁢ power switching device) and ‌runs only during designated ‌drain steps or when⁢ a diagnostic routine commands it; the board sequences the pump with inlet valves, heaters, and ⁢sensors to ‍maintain correct water ⁤levels and timing.⁤ Common operational⁤ behaviors⁣ and diagnostic clues include: a humming ⁢motor with no flow (blocked ​impeller or debris in the strainer), continuous‌ running ‌(stuck control output or a failed level/float sensor), or intermittent operation (loose connector ⁣or thermal protection cycling). Practical troubleshooting steps‌ for technicians often begin​ with verifying the control signal and line voltage⁢ at the⁢ pump connector,‌ inspecting the rotor and strainer for obstructions, and confirming that the drain path and hose are free‌ of kinks or restrictions before replacing the assembly.

  • symptoms: no drain, humming, intermittent flow – map to likely⁣ causes such ⁢as electrical, mechanical blockage, or control logic faults.
  • behavior:⁣ pump runs only when commanded by‌ the control board and may include thermal overload protection that opens​ during⁤ stall/overcurrent.
  • Compatibility: confirm part number,connector type,and mounting orientation to ensure correct replacement and hydraulic alignment.
Item Description
Mounting interface Molded flange and screw/tab locations that align⁣ with the appliance base and tub outlet.
Electrical connection Two or three-pin plug⁤ to the main wiring harness; switched by control board⁤ relay/triac.
Function Centrifugal impeller evacuates⁢ tub water into drain hose; prevents backflow by molded path or check geometry.
Common failure modes Impeller clogging, bearing wear, thermal overload activation, or connector ​corrosion.

Common Failure Symptoms and Visual/Electrical Indicators of Pump or Motor⁢ Malfunction

The 137108000 Frigidaire Water Drain Pump and Motor Assembly provides the ⁣mechanical and‍ electrical interface that evacuates water ⁣from the appliance sump; it is an integrated pump-and-motor unit intended as a direct-fit OEM replacement on compatible Frigidaire machines.​ In normal operation the motor drives an impeller to generate flow through the discharge port, so failures manifest as hydraulic symptoms (reduced flow, partial drainage, or⁣ complete blockage) or electrical symptoms (no run, intermittent run, or abnormal noise). Becuase‌ the pump and motor ⁤share the same housing and mounting, a mechanical fault such as a clogged or broken impeller can produce the same customer-visible ‌behavior as⁤ an electrical fault,​ which makes combined visual inspection and ‍electrical testing necessary to determine weather the assembly or an external control/component must be replaced.

  • No rotation – motor receives supply ​but shaft does ⁢not turn; check​ for impeller obstruction, debris in​ the housing, or a seized bearing.
  • Humming or ⁣clicking -⁣ audible motor noise without full spin can indicate a locked rotor, failed start device, or intermittent supply from a relay or control board.
  • Intermittent operation – pump runs sporadically due to wiring‌ harness issues, corroded connectors, or thermal cycling inside the motor windings.
  • Reduced flow/slow drainage – partially blocked discharge, worn impeller,​ or degraded motor torque from‍ winding damage.
  • Visible damage or contamination – cracked housing, oil/grease​ contamination, or water ingress that corrodes electrical​ connections or bearings.

When diagnosing,​ perform⁢ a‌ visual inspection for physical damage and debris, then ​verify electrical conditions: confirm correct supply voltage at the pump⁤ connector, measure motor winding continuity and insulation to ground, and monitor running‍ current with a ‍clamp meter to detect excessive draw from bearing drag or a ⁤shorted winding. practical examples: a motor that hums but draws low current and shows open winding resistance points ⁤to an electrical failure; a motor that hums with high current and elevated temperature indicates mechanical seizure or bearing failure. If mechanical clearance cannot be restored or if windings are open⁢ or shorted to‌ ground, replacement of‌ the 137108000 assembly is ​the practical solution as the unit is supplied as an⁤ integrated pump-and-motor​ component.

Item Description
No rotation Power present ⁣at connector but shaft stationary – inspect impeller, ⁤shaft play, and motor winding continuity.
Humming ⁣/ ⁤high current Audible ‌motor noise with elevated current – suggests locked rotor, ‍bearing failure, or shorted winding.
Intermittent run Variable⁤ operation often caused by‌ corroded connectors,⁤ wiring harness ‍faults, or failing control relays.

Compatibility and Approved Appliance Models for ‍the 137108000 Frigidaire Water Drain Pump and Motor‌ Assembly

The 137108000 Frigidaire ‍Water Drain pump and Motor Assembly is a combined impeller pump⁢ and compact motor designed⁤ to evacuate water from the appliance’s sump or wash tub. Its mechanical and ‍electrical interfaces determine whether it will operate correctly in a given ⁢appliance: the⁤ mounting⁤ flange, ⁢screw⁣ pattern, sump⁣ seal diameter, impeller orientation, and the electrical ⁣connector pinout must match ‍the original unit.Performance behavior to check includes torque under load (ability to​ clear obstructions), direction of rotation, ​and whether the motor’s capacitance/drive characteristics match ​the ⁤washer’s control board; ⁣differences in those parameters can cause reduced flow, overheating, or intermittent operation even when the unit physically‍ fits.

  • Mounting ‌compatibility: matching bolt pattern and⁤ shaft alignment.
  • Electrical compatibility: ‌identical connector type and voltage rating or confirmed ‌equivalence.
  • Hydraulic compatibility: impeller size, inlet/outlet diameter, and discharge orientation.
  • Service compatibility: available cross-reference or OEM‍ approval in parts lists.

Approved appliance models are persistent by manufacturer ‍cross-reference charts and service manuals rather than by ​visual similarity alone; technicians ⁤should confirm the ‍part number against the appliance model/serial number or Frigidaire parts lookup before installation.In practice, replacement is typically accomplished when the physical dimensions and electrical connections match exactly – such as, swapping a failed drain pump that shares the same ⁢mounting flange and 3-pin connector without modifying ​the sump. When in doubt, inspect the original pump label and consult the appliance’s‌ replacement parts list to avoid installing a‌ unit with incompatible motor characteristics or an incorrect seal that could cause leaks or premature failure.

item Description
Part number 137108000 – verify‌ this number against the label on the original pump​ and the appliance parts list.
Compatibility factors Mounting pattern, ⁣seal⁣ diameter, connector pinout, impeller orientation and motor⁢ drive characteristics.
Common ‍symptoms No drain, motor ⁤hum without impeller movement, intermittent drainage, or water leakage ⁤at ‌the pump seal.
Verification step Compare mechanical dimensions and connector type; consult Frigidaire parts lookup or the appliance service manual for approved model cross-references.

Replacement Considerations and Installation Procedures: Mounting, Seals,⁣ Wiring, and⁣ Torque Specifications

The 137108000 Frigidaire ‍Water Drain Pump and ⁢Motor Assembly is a compact centrifugal pump and plated motor⁤ intended to remove process ‍and condensate water from laundry and refrigeration appliances. When replacing this unit, check mechanical compatibility:​ the pump housing flange, mounting hole pattern, and gasket face must match the appliance sump or drain channel to maintain a reliable seal. Inspect the pump’s elastomer seal ⁢and the mating surface for flatness and debris; ​a distorted mounting surface or torn ⁢gasket will‍ allow air ingestion⁢ or leaks that change​ pump behavior (noise, reduced ‌flow, or intermittent operation).Use the OEM part number to confirm fitment and note that small‍ differences ‌in inlet/outlet ‍orientation or⁢ mounting boss elevation ⁢can require​ minor repositioning of hoses‌ or brackets during installation.

Electrical and ‌torque details directly affect long-term ⁣reliability. Disconnect mains power before accessing‍ wiring and ​confirm the pump’s rated‍ voltage on the nameplate; ⁢many assemblies use a keyed 2- or 3‑pin connector that should be checked for corrosion and correct pinout with a multimeter before re-energizing. Tighten mounting hardware to avoid over‑compressing plastic housings while achieving⁤ a secure interface; typical small pump mounting screws are tightened to a low torque to prevent stripping-verify the appliance service ‌manual for the exact value and record it for future service. After installation, secure wiring away from the impeller and moving components, run a short powered test per the service procedure to confirm rotation and noise-free operation, and perform a water leak check under normal​ drain conditions.

  • Verify OEM part number and physical fit before installation.
  • inspect and replace gasket/seal if damaged; clean mating surfaces.
  • Confirm⁢ connector pinout and ⁣rated voltage; test continuity and insulation.
  • Tighten mounting hardware to ‍specified torque‍ and ‌avoid housing distortion.
  • Perform operational and leak tests after installation.
Item Description
Mounting interface Match flange and hole pattern; replace gasket⁤ if compressed or torn.
Torque guidance Small sheet‑metal or ⁣machine screws into plastic housings-use low torque and consult service manual ⁤(common range for similar‍ assemblies: 8-12 ⁣in‑lb / 0.9-1.4 N·m).
Wiring Keyed 2-3 pin connector; confirm voltage and perform continuity/isolation checks before ​power-up.

Troubleshooting and⁣ Diagnostics: Multimeter Tests,Bench Testing the Pump/Motor,and Interpreting Fault Codes

The 137108000 Frigidaire Water Drain Pump and Motor ⁤Assembly can be diagnosed ⁢with ⁢basic‌ multimeter‌ checks and a short bench test to distinguish electrical⁣ faults⁤ from mechanical failures. With the pump disconnected⁣ from the⁢ appliance, use a ⁤multimeter to measure DC or AC continuity and ‍the⁤ DC resistance across the motor terminals; a healthy stator will show a stable low-ohm reading rather than an open circuit, and there should be no low-resistance path from any terminal to chassis (indicating a short to ground). Inspect the molded connector and wiring​ for corrosion or broken pins that can cause intermittent operation. For⁤ a bench functional test,securely mount ⁢the assembly,apply the rated supply voltage shown on the appliance wiring diagram ‍(often 120 VAC in North American models) using a GFCI-protected source,and verify the ‌impeller turns freely‌ and pumps ⁢water; a⁢ humming motor with ​no rotation typically indicates mechanical seizure,blocked discharge,or internal rotor/stator damage rather than a control issue. ⁤Confirm physical compatibility (mounting flange, connector pinout, and impeller orientation) before substituting replacement units to ensure the assembly integrates with the ⁢control and plumbing of the appliance.

Electronic control fault codes normally map to a small set of conditions-no drain ‍detected, excessive motor current, or motor circuit open/short-and should be interpreted​ with the‍ appliance⁢ service sheet. A persistent drain​ error while the control supplies correct voltage to the pump⁤ suggests a hydraulic blockage,collapsed ​drain hose,or a mechanically‌ jammed ⁤impeller; a code ‌indicating ‌motor fault with out-of-range resistance or leakage points to windings that must be replaced. Use the following checklist to proceed methodically: check wiring and connectors, measure terminal ​voltage during a drain cycle, verify ⁣motor winding resistance ⁣and insulation, bench-run the pump under the rated supply while measuring ​current, and consult the control’s fault-code⁤ table to‍ correlate measurements to failure modes. Replace the 137108000 assembly when windings ⁢are open/shorted, insulation resistance is low, current draw significantly exceeds the reference range, or ​the impeller cannot be freed during safe bench testing.

  • Check connector continuity and ​pin condition before electrical testing.
  • Measure resistance across motor terminals and to chassis (expect no continuity to ground).
  • Measure applied‍ voltage ‍at the connector⁤ during a drain command before bench ‍powering.
  • Bench test with the correct rated supply and a GFCI; measure⁤ current⁣ draw and observe ⁤impeller behavior.
  • Compare findings to the appliance service⁢ manual fault-code table and replace if ​windings are defective ‌or the pump ⁤is mechanically seized.
Item Description
Typical coil resistance Manufacturer-specific;‌ commonly in the low-ohm range (consult service sheet).Verify for open/short conditions.
Expected supply voltage at command Appliance wiring diagram specifies rated value (frequently enough 120 ⁢VAC ⁢on North American‍ models); verify before‍ applying bench power.
Insulation ‍to⁣ chassis High/OL on​ multimeter; any measurable low resistance indicates leakage and requires replacement.
Current draw while⁢ running Compare to service spec; ‌a substantially⁣ higher ⁣current indicates mechanical⁣ binding or internal ⁣motor fault.

Q&A

What models is the 137108000 Frigidaire ‍Water⁢ Drain Pump and Motor assembly compatible with?

The 137108000 ‌is an ​OEM drain pump⁣ assembly used on‌ a range of Frigidaire appliances. Compatibility varies by model and ⁣year, so always verify fit by ‍checking⁣ your appliance model number ‍(usually on ⁣a⁣ tag ‍inside⁤ the door or on the back) and cross-referencing it with the part ⁢seller ‌or Frigidaire parts lookup. Compare mounting ​points,connector pinout,hose sizes ⁣and overall shape to be sure ‍it will fit and function correctly.

What are common symptoms that the drain pump/motor assembly is failing?

Common symptoms include: appliance does​ not‌ drain at all, long drain⁣ cycles or error codes related to draining, ⁣a humming sound ‍without water movement (motor stalled), loud grinding or rattling (impeller damaged or foreign object), ⁣or visible leaks⁣ from the pump⁢ housing. Before replacing the ‍pump, check filters, drain hose clogs, and the sink/disposal ⁣connection.

How can a ⁢technician ⁢test the 137108000 pump to⁢ determine if the motor is bad?

Start with safety: unplug the appliance and turn ​off the ​water. Visually inspect for obstructions and check‍ the impeller for free rotation ⁣by hand. Use a multimeter to check for continuity across the pump motor terminals-an open⁢ circuit usually means a failed‌ motor. To check operation‍ under load, reconnect power and activate a drain cycle while measuring the supply voltage at⁤ the pump connector (verify ‌your appliance wiring diagram first). ​If proper voltage ‍is present and​ the pump does not run, ⁤the motor is faulty. Do not run the pump‍ dry for extended​ periods.

What tools and parts ​do I ‌need to replace the 137108000 pump assembly?

Typical tools: screwdriver set (Phillips and flat),nut driver or socket set,pliers,multimeter,bucket/towels,and possibly a trim⁤ tool to release panels. Replacement parts: the 137108000 pump assembly itself and any⁣ gaskets, clamps or hoses that⁣ are worn. Keep ‌replacement wire​ connectors or zip ties handy if harness clips are brittle.

What are the ​basic steps to replace⁣ the drain pump assembly safely?

1. Unplug the appliance and turn off ​water⁤ if applicable. 2.Place towels/bucket under the pump area to catch residual water. 3. Remove the access panel(s) to reach the pump. 4. Photograph the wiring and⁢ hose ⁣connections for reference. 5. disconnect the ⁤wiring harness and ⁤drain hoses (beware⁣ of water spillage). 6. ‌Remove mounting screws/clips and take​ out ⁢the old pump. 7. Install the new pump, transfer any ⁣brackets or⁣ gaskets, reconnect hoses and ‍wiring⁢ per the photos. 8.Reassemble ‍panels, restore power/water, and⁣ run a short ⁤cycle to⁤ check for ‍correct operation and leaks.

Can a clogged drain or foreign⁢ object be cleared without ‍replacing the pump?

Yes-many drain issues ⁢are caused by debris, broken glass, labels, or small objects ‍jamming the impeller or filter.⁢ After disconnecting power, access the pump and remove the impeller cover or ‍filter (if present) ‌and clear obstructions. If the⁣ motor runs freely and the pump moves water after cleaning, ⁢replacement isn’t necessary.however, damaged impellers, cracked housings, ​or⁤ burned motors will‌ require replacement.

What electrical precautions should I take when​ diagnosing or replacing the pump?

Always disconnect mains ​power before​ touching wiring or removing the pump. ⁢If ​you must ​measure voltage while the appliance ⁣is running, be cautious, use insulated tools, and avoid shorting terminals; better to have a qualified technician perform ⁤live tests. Verify wiring harness orientation and⁤ secure connections-incorrect wiring can damage the motor or controls.

Does the 137108000 pump assembly come with a warranty, and what should I check after installation?

Warranty⁤ terms vary by supplier-OEM parts ⁢often‌ carry a limited parts warranty (e.g., 90 days to 1 year). Keep your purchase receipt and part number. After installation,‍ run a full drain cycle and inspect ⁤for proper drainage, unusual noises, and leaks around hose connections and⁣ the pump housing. Recheck mounting screws ⁢after ⁢a trial cycle to ensure nothing has loosened.

To Wrap It Up

The 137108000 Frigidaire water Drain Pump and Motor Assembly plays a central role ⁣in the proper ⁢operation ‍of compatible Frigidaire appliances by moving wastewater out of ⁤the appliance during drain cycles. ​As a mechanical and electrical subassembly, it directly affects cycle completion,‍ appliance hygiene, and⁤ the prevention of standing water or overflow conditions, making⁣ it a key component for reliable performance.

Accurate ‌diagnosis is essential before replacing the ⁣pump assembly. Symptoms ⁤such as poor‍ or slow draining, persistent‌ standing water, unusual noises during drain cycles, ⁤or appliance error codes can ⁢indicate pump failure but may also result from clogs, kinked hoses,‍ or control​ issues. Inspecting filters and​ hoses, listening for motor activity, and testing electrical continuity help identify the root cause and avoid unnecessary part replacement.

When diagnosis confirms a faulty pump​ or motor,‍ replacing the ‌unit with ‍the correct 137108000 assembly can restore normal operation, reduce the risk of water damage, and help preserve overall appliance longevity. Proper installation, adherence​ to safety procedures, and consideration of OEM or ​equivalent⁣ quality parts are recommended; where ​uncertainty exists, professional service⁣ ensures the ⁤repair is completed safely and ⁣effectively.


Professional Appliance Service

If your appliance requires professional diagnosis or repair, visit

Revolff Home Services
for expert appliance repair services.

For local appliance service information see

Dryer repair Henderson
.

Replacement parts for many appliance models can also be found at

Reliable-Parts-Hub
.

Recommended Products