In the world of electrical components, reliability and precision are paramount. The 5945-002-74-20 Jackson Contactor, model Cr453Cc2Baa, stands out as a genuine OEM part designed to meet the demanding needs of modern electrical systems. rated at 30 amps and 240 volts, this GE contactor offers robust performance and durability, making it an essential choice for professionals seeking dependable switching solutions. Whether used in industrial machinery, HVAC systems, or other electrical applications, the 5945-002-74-20 combines trusted engineering wiht proven functionality to keep your operations running smoothly.
Understanding the Features of the Jackson Contactor Cr453Cc2Baa
The Jackson Contactor Cr453Cc2Baa is engineered for reliability and efficiency, boasting a robust 30Amp capacity paired with a 240V rating, making it an ideal choice for heavy-duty switching applications. Its design incorporates durable materials that withstand high electrical loads and harsh operating conditions, ensuring longevity and minimal maintenance.This genuine OEM component fits seamlessly within existing GE systems, reducing downtime with its precise specifications and easy installation features.
Key aspects that set this contactor apart include:
- Compact form factor that saves space in control panels
- Enhanced thermal protection to prevent overheating during continuous operation
- High contact resistance tolerance for stable current flow
- Corrosion-resistant terminals ensuring consistent connectivity
Feature | Specification |
---|---|
Current Rating | 30 Amps |
Voltage | 240 Volts |
Contact Type | normally Open (NO) |
Mounting | DIN Rail Compatible |
Performance Benefits of the 30Amp 240V Ge Genuine OEM Model
Optimized electrical efficiency is at the core of this contactor’s design, enabling smooth and reliable operation within 30Amp 240V systems. Its genuine OEM construction ensures consistent conductivity and minimal voltage drop,which translates to reduced energy waste and steady power delivery. Users benefit from prolonged equipment lifespan thanks to reduced heat generation and enhanced load handling capabilities, making it ideal for high-demand applications.
Additional performance advantages include:
- Durable contact surfaces that resist pitting and corrosion
- Fast response times for seamless switching and reduced operational lag
- Compact and robust build tailored for heavy-duty industrial use
Feature | Benefit |
---|---|
30Amp Rating | Handles ample current loads without overheating |
240V Compatibility | ensures stable performance across common voltage requirements |
OEM Build Quality | Precision-engineered for guaranteed fit and maximum reliability |
Installation Tips for Optimal Use and Longevity
Ensuring the Jackson Contactor 5945-002-74-20 operates at peak performance starts with proper installation. Begin by confirming the electrical panel is de-energized to guarantee safety during setup. Use a torque wrench to tighten terminals to the manufacturer’s specifications, avoiding both under-tightening and over-tightening, which can lead to connection failures or overheating. Additionally, the contactor should be mounted securely on a clean, vibration-free surface to prevent mechanical stress and premature wear.
- Verify wiring matches the 30Amp, 240V rating exactly to prevent damage.
- Implement proper wire gauge and insulation standards to maintain optimal conductivity.
- Keep the contactor away from moisture or corrosive environments to extend lifespan.
- Periodically inspect for dust buildup and clean gently with a dry cloth.
Installation Aspect | Recommended Practice |
---|---|
Terminal Tightening | 25-30 in-lbs torque |
Mounting Surface | Vibration-free metal panel |
Environmental Conditions | Dry, well-ventilated enclosure |
Wire Specifications | 12-14 AWG copper |
Maintenance Practices to Ensure Reliable Operation
Consistent upkeep is crucial for maximizing the longevity and efficiency of the Jackson Contactor,Cr453Cc2Baa 30Amp 240V. Begin by implementing a routine inspection schedule that checks for signs of wear, corrosion, and loose connections. Pay particular attention to the contact points and coils, as thes are common stress zones. Use a soft brush or compressed air to clear away any dust or debris that could interfere with electrical conductivity. Regular lubrication of moving parts with manufacturer-approved products ensures smooth operation and minimizes the risk of overheating.
In addition to physical cleaning, electrical testing is vital. Employ a multimeter to measure resistance values and verify voltage levels, confirming they align with the specifications outlined in the user manual. Consider the following maintenance checklist to streamline your process:
- Visual inspection: Look for discoloration or burnt marks
- Tighten terminals: Prevent loose connections
- Test coil resistance: Ensure coil integrity
- Clean contacts: Avoid pitting and oxidation
- Replace worn parts: Maintain reliability
Maintenance Task | Recommended Frequency | Tools Required |
---|---|---|
visual Inspection | Monthly | Flashlight, Screwdriver |
Contact Cleaning | Quarterly | Contact Cleaner, Soft Brush |
Electrical Testing | Bi-annually | Multimeter, Insulation Tester |
Lubrication | Annually | Light machine Oil |
To Conclude
the 5945-002-74-20 Jackson Contactor, Cr453Cc2Baa 30Amp 240V by GE stands as a reliable and precise component engineered for optimal performance in electrical systems. Whether you’re maintaining existing setups or embarking on new installations, this genuine OEM part ensures durability, safety, and efficiency. Its trusted design underscores GE’s commitment to quality, making it a smart choice for professionals and enthusiasts alike.As you consider your next electrical project, the Jackson Contactor remains a steadfast solution that balances functionality with dependability-quietly powering progress behind the scenes.