WB28K142 – Gas range burner orifice spud natural gas 1.52 MM.Appliance Part, Replacement

in the intricate world of home cooking, even the smallest components play a vital role in delivering consistent performance. The WB28K142 Gas Range Burner Orifice Spud for ‌natural ‌gas, measuring 1.52 mm, ​is one​ such essential appliance part that ensures your stove’s burners operate ⁤efficiently ‌and safely. Designed as a precise replacement piece, this ⁢orifice spud regulates the ‌flow⁣ of natural gas to the burner, influencing‍ flame quality and overall ‍cooking results. Whether you’re​ tackling a simple weeknight dinner or preparing a gourmet feast, understanding and maintaining parts like​ the ⁤WB28K142 helps keep your gas range running⁣ smoothly and reliably.

Understanding⁤ the‌ Role of the⁣ WB28K142​ Gas Range Burner Orifice in Natural Gas‌ Appliances

The WB28K142 gas⁢ range burner orifice plays a critical ‍role in ensuring that natural gas​ appliances operate efficiently and⁢ safely. This⁢ small, ‍yet essential ‍component controls the flow of gas into the burner, regulating the size and intensity of the flame. A precisely ⁤calibrated​ orifice ⁢diameter of 1.52 mm⁤ ensures that the⁣ natural gas mixes correctly with air to produce a clean, consistent burn. ‌Without a‍ properly functioning orifice, burners may suffer from ​incomplete combustion, leading to wasted gas, unstable flames, or even hazardous ‍conditions like carbon ⁤monoxide buildup.

Maintaining and replacing the WB28K142 ‌orifice can substantially improve the performance‌ of your gas range.⁤ Its durable construction withstands high‌ temperatures and prolonged use, making it a reliable replacement part for various natural gas‍ appliances. Below is a quick overview of its essential‍ characteristics:

Feature Specification
Diameter 1.52 mm
material High-grade brass
Compatibility Most natural ⁤gas ranges
Function Regulates gas flow to burner
  • Ensures optimal flame ‍control for‍ efficient cooking
  • Prevents gas leakage by fitting securely
  • Easy to replace with ​standard tools
  • Enhances safety by⁢ maintaining proper combustion

Key Features‍ and ​Specifications of the 1.52 MM Burner Orifice Spud

The 1. is engineered specifically for ⁣natural gas​ applications, ‍ensuring precise⁢ flame control and efficient fuel consumption. Crafted from durable materials, this component guarantees ‍long-lasting⁢ performance even under‌ continuous high-heat conditions. Its standardized diameter size ​of⁣ 1.52 mm ​enables compatibility with a ⁤wide range of gas ranges, simplifying replacement procedures without‌ the need​ for adjustments or​ additional parts. Designed for ⁢seamless installation,⁤ this ⁤orifice ​spud optimizes the air-to-gas mixture for consistent flame output, improving⁤ overall burner efficiency.

  • Material: Corrosion-resistant ‍brass
  • Diameter: 1.52 mm precision aperture
  • Gas type: Natural Gas optimized
  • Compatibility: Universal fit for ⁤many residential gas ranges
  • Installation: Easy drop-in⁢ replacement without modifications
Specification Details
Orifice Size 1.52 mm
Gas‍ Type Natural Gas
Material Brass
Request Gas Range Burners
Replaceability Direct ⁢Fit

step-by-Step Guide​ to Replacing Your WB28K142 Burner Orifice Safely and Effectively

Before​ diving into the ​replacement process, make⁤ sure to turn​ off the gas supply and unplug your range⁣ to prevent any accidents. Safety should always ⁣be your‍ top priority. Gather ⁤the⁢ necessary tools ⁢such as ‌a wrench, screwdriver, and a⁣ soft cloth to ‌avoid scratching your appliance. Begin‌ by carefully removing the burner cap and head to expose the orifice ⁢spud.⁣ take note ⁢of the original part’s ‍specifications⁣ and compare it with the new WB28K142 ​orifice to ensure ⁣it‍ matches‍ the 1.52 MM‌ size designed specifically ​for natural gas. Gently unscrew⁢ the old orifice with the wrench, keeping a firm grip to avoid dropping it into the burner assembly.

Once the old spud ⁣is removed, clean the ⁢area around the burner to clear any‌ dirt or debris that ‍could clog the orifice and impair performance.Install the new WB28K142 orifice by threading it‌ into place and tightening it snugly-avoid overtightening to prevent damage. Reassemble the burner head​ and cap, double-checking alignment for proper ​flame distribution.restore⁤ the⁣ gas supply and power, then ignite the burner to test‍ for a steady,⁣ even flame. Hear’s a quick ⁤checklist ‍to keep ⁢you on track:

  • Turn off ⁢gas and unplug appliance
  • Remove burner cap and head
  • Unscrew‌ and remove⁢ old orifice
  • Clean burner ​area thoroughly
  • Install new WB28K142 orifice
  • Reassemble burner⁣ and test flame

Tips for ​Maintaining ‌Optimal Performance and Longevity of Your Gas⁣ Range Components

Ensuring your gas range operates at peak‌ efficiency requires regular attention to its burner components, especially the orifice ⁤spud. Keep the burner ports free of debris and ‍food particles by gently cleaning them with⁤ a soft brush or a specialized cleaning tool. Avoid using metal ⁣objects that might damage the delicate openings; a clogged orifice can‌ cause uneven flames and reduce cooking⁢ performance.‌ Periodically check the burner assembly​ for signs of wear‌ or corrosion, replacing parts promptly⁤ to prevent leaks and maintain ​consistent gas flow.

Maintaining the overall integrity of ⁤your⁤ gas range also involves routine checks of the ignition ‌system and gas lines.‌ Follow these‌ essential⁢ practices:

  • Turn off the gas supply before⁤ performing ⁢any maintenance to ensure⁣ safety.
  • Inspect connections for cracks ‍or loose fittings that‌ could cause gas⁢ leaks.
  • Clean⁢ the burner caps with mild soap and⁢ water to remove grease buildup.
  • Schedule⁤ professional‍ inspections annually to certify⁤ all components‍ meet safety standards.
Maintenance Task Recommended Frequency
Burner Port Cleaning Monthly
Ignition System Check Every 6 ‍months
Gas Line Inspection Annually
professional Service Annually

The Conclusion

in the world of kitchen appliances, ‌sometimes ⁢the smallest parts make the biggest ⁤difference. The‌ WB28K142 gas range burner orifice spud, with its precise ‍1.52 mm opening for natural ‍gas,is a subtle yet essential component ‌that ensures your stove operates safely‍ and‍ efficiently. Whether you’re repairing a favourite ​cooking range or simply⁣ maintaining your​ appliance, choosing the right replacement part like this⁢ one helps restore reliable performance and peace of ⁤mind.⁣ Remember, in keeping your kitchen running smoothly,​ attention to detail is everything-and the WB28K142 orifice spud‌ is ⁢a perfect example of that principle in ‌action.

Leave a Reply

Your email address will not be published. Required fields are marked *