137108000 Frigidaire Water Drain Pump and⁢ Motor⁢ assembly ‍is an electromechanical⁤ drainage component used in ⁢Frigidaire laundry ‍appliances.⁤ It combines a compact electric motor with an impeller and housing to move water out of the wash tub ‌or ⁤sump‌ and into the​ household drain. The assembly typically includes the motor ‍rotor and stator, a molded⁤ plastic pump body, mounting features and an⁤ electrical connector, making it a replaceable service module in the‍ appliance’s fluid-handling system.

Within​ the​ appliance, the⁣ drain pump/motor​ assembly provides the mechanical‌ action required to evacuate ⁤water at the end⁤ of fill⁣ and wash stages and prior to⁤ spin or drain-only cycles. It interfaces mechanically with the tub or sump outlet and hose, ⁤and electrically with the main control ​board ‌and safety interlocks that sequence drain operations. Proper operation​ depends on ⁤clear⁣ hydraulic flow paths, ⁢an intact⁣ impeller and ⁤seal, correct electrical supply ‍and‌ control signalsand coordination with ‌sensors such⁢ as water-level⁣ switches‌ and door locks to ⁣prevent operation when unsafe.

This article‌ will describe the assembly’s functional design and ‍typical usage,outline compatibility and⁢ identification ⁤considerations for technicians and owners,list common failure symptoms (such as no-drain,intermittent operation,unusual noise or leakage),and⁣ present practical troubleshooting⁣ steps and replacement considerations. topics include inspection‍ for obstructions and leaks, ‍basic⁤ electrical ⁣and ‍continuity checks, verification of control signals, mounting‌ and sealing requirements during replacementand ⁣guidance‍ on matching ‌connectors and mechanical fit to ensure reliable service restoration.

Table of Contents

function and⁢ role and Performance Requirements of ​the Dishwasher Drain Pump and Motor Assembly

The ‍ 137108000 frigidaire Water Drain Pump and Motor Assembly is‌ a compact electromechanical unit that evacuates ⁣wash and rinse ⁤water⁢ from the ⁢dishwasher sump⁤ thru the drain hose and check valve. ​The assembly‍ combines‍ a small sealed motor, an impeller and ​a housing with seals ⁢and mounting points; the motor provides the torque and⁣ head needed‌ to ⁢overcome the ​drain ​trap⁣ and household plumbing backpressure while the impeller produces the required flow. Compatibility‍ depends on the ⁤electrical⁣ connector, ⁣mounting footprint and gasket orientation, so replacement requires matching​ those interfaces to the original⁣ unit. Technically, the motor is designed for short-duty, wet-environment ⁣operation with ⁣thermal protection ⁢and a shaft​ seal to limit water ingress; common verification checks include listening for motor hum, measuring winding continuityand inspecting⁤ the impeller and inlet for blockages⁣ or mechanical damage.

  • Common symptoms and ​diagnostics: ‌no drain with motor silent (electrical ‍fault or open circuit), humming without⁣ flow (blocked impeller⁤ or ‍seized shaft), ⁤slow drain (partial blockage)and leaks (seal⁢ or housing damage).
  • Performance expectations: provide sufficient flow‍ and⁤ head to clear the sump‍ within the drain phase,‌ resist backflowand tolerate ⁢detergents and suspended ​food particles for the rated service ‍life.
  • Installation considerations: ‌ensure ⁢correct electrical polarity/connections,secure mounting to prevent vibration,and⁢ replace gaskets to maintain a ​watertight seal.

In ‍practice, ⁢technicians should treat ‌the pump assembly as a replaceable‍ hydraulic-motor subsystem: inspect ⁤for foreign⁢ objects ‌in the inlet screen, check the coupling between motor and⁢ impeller for wearand ‍confirm the control signals that energize the pump (timer/PCB or pressure/float switches). Field troubleshooting examples include isolating ​the pump from the control ⁢board​ to verify‍ direct ⁤power operationand testing for proper backflow prevention ‌by observing‌ drainage with ⁢the unit energized and then de-energized. Selecting the correct 137108000 assembly or approved ⁤equivalent ⁤ensures ‌electrical⁢ rating,​ mounting alignment and sealing details match the machine, avoiding ⁢vibration, premature ​failureor leaks‍ after service.

Item Description
Model 137108000 Frigidaire Water drain Pump and Motor Assembly
Voltage Nominal 120 V AC (North ⁢American ⁤models); verify label for other regions
Function Evacuates ⁤sump water⁣ to household drain; includes impeller,motor and seal
Common failure symptoms Humming without flow,no ⁤drain,slow drain,leaks,continuous⁤ or intermittent operation
Installation notes Match electrical connector,mounting tabs and‍ gasket ‍orientation; replace seals when servicing

How the 137108000 Frigidaire Water Drain Pump and Motor Assembly Operates Inside ⁣the Appliance: Electrical,Mechanical and Fluid Dynamics

The 137108000 Frigidaire Water Drain Pump⁣ and Motor Assembly is a compact electromechanical unit that⁤ receives a timed ⁣electrical drive‌ signal from the appliance control​ board and ‍converts that energy into centrifugal flow to evacuate wash​ water. Inside the assembly a sealed electric motor turns a ‍molded plastic impeller seated in a volute within the pump ‍housing; as the impeller​ spins it accelerates​ fluid radially,​ creating a pressure differential that routes water ⁣out through the drain hose ⁣and check valve. The ⁤motor type (single‑phase AC or low‑voltage DC)‍ and⁤ connector style vary by⁢ model, so functional compatibility​ depends ‌on ‍matching the electrical supply, mounting flange, ⁤and discharge orientation to the appliance chassis and ⁣control harness.

The pump’s ​mechanical and fluid dynamics determine real-world behavior:⁢ impeller geometry and volute shape set the flow‌ vs. head⁢ curve, while ‌clearances​ and seal‍ integrity govern leakage and bearing life. common​ failure modes include impeller blockage (debris or small garments), shaft/bearing⁢ wear ⁢that‌ increases ‌torque and draws excess current, ‍and seal⁤ deterioration that permits water ‌intrusion ⁢into⁤ the motor cavity. Technicians commonly diagnose issues with ‍simple checks – ⁤listening for motor hum without rotation, checking current draw, inspecting the discharge for​ restrictions, ⁣and performing a continuity test on the motor windings – and⁣ should replace the unit with a ​part that matches electrical rating,​ mounting tabsand hose fitting to restore expected flow and‌ prevent ​cavitation or overheating.

  • Quick⁤ diagnostics: humming/no spin (jammed impeller), no power⁣ at connector (electrical/control fault), ⁤leak at housing (seal failure), intermittent run (thermal protector cycling).
Item Description
Motor Provides ‌rotational torque; must match ⁤appliance voltage and connector ⁣pinout.
Impeller Creates centrifugal flow;​ geometry sets flow/head characteristics and ⁤sensitivity to debris.
Housing & Seal Directs flow and protects‌ motor;⁣ seals prevent water⁢ ingress and ⁣bearing contamination.

Common Failure ⁢Modes ​and ‍Diagnostic Symptoms for the Drain Pump⁤ and ‍Motor Assembly

The ⁣137108000 Frigidaire Water Drain Pump ⁣and motor Assembly evacuates defrost and​ condensate water from evaporator trays‌ and drain pans, converting electrical input into impeller-driven flow. Common failure⁢ modes include mechanical⁢ obstruction of the impeller by debris or⁤ ice, bearing ⁤wear that produces high vibration ‍and⁢ noise, impeller or housing damage that reduces flowand electrical faults such as open or shorted motor windings or intermittent connector corrosion.Compatibility ⁢during replacement ⁢is primarily⁣ mechanical and⁤ electrical: the replacement must match mounting points, connector ‍type, rotational direction,‌ and the OEM-specified‍ voltage and ⁢current rating to ensure proper fit and correct⁢ pump performance in​ the appliance plumbing and control system.

Diagnostic symptoms ⁢map directly to ​likely failure mechanisms and can‍ be verified with basic tests. Typical observable symptoms include no pumping despite applied ⁤voltage (indicating a ⁤seized impeller,broken coupling,or ‌open winding),a humming motor with⁣ no flow (mechanical ‍jam or⁤ stuck impeller),continuous running​ without‍ removing water (check check valve or‍ impeller damage),excessive noise ‍(bearing or rotor imbalance),and tripping breakers or high current ‌draw (electrical ⁤short or mechanical binding). Practical diagnostics include a​ visual inspection for debris ⁢at the inlet, a manual ​spin‍ test‌ of ‍the ⁢impeller ⁢with power removed, voltage measurement⁢ at‍ the pump connector while the unit‍ is calling for drain,‍ and an amp draw check under load to⁤ compare against the ⁤appliance service specification.

  • No output but ⁢motor hums – likely⁢ mechanical⁤ jam ‍or slipped/broken coupling.
  • Intermittent operation ⁣- suspect corroded‌ connectors,thermal protector‍ cycling,or control board signal ⁣issues.
  • Loud grinding or vibration -​ worn bearings⁣ or rotor contact with housing.
  • High current​ or tripping – possible​ winding short or mechanically bound impeller.
Item Description
Electrical checks Measure voltage at the pump connector during⁣ a drain cycleand​ measure motor current to detect overloads.
Mechanical checks Inspect and free the impeller, ​confirm free rotationand verify inlet/outlet passages ‍are clear.

Compatibility, Replacement⁣ Considerations ​and Installation Procedures for the 137108000 Frigidaire Water Drain Pump and Motor Assembly

The 137108000 Frigidaire water ‍Drain Pump and Motor Assembly‍ is a⁢ compact, sealed pump/motor module‌ that evacuates standing and‍ process water from ⁤the ⁣appliance by driving a molded impeller through a short ⁣volute. Functionally, the assembly‍ combines the pump ‍hydraulics​ and the drive⁢ motor​ in a single replaceable unit; compatibility‍ is‌ determined by electrical connector type, mounting boss geometry, hose‌ diameter⁢ and impeller orientation​ rather ⁣than by brand ⁢name alone. Technicians should inspect the electrical plug, mounting flange ​and the position ⁢of the discharge outlet on the service label and housing to verify that a replacement‍ will mate ‍without modification. Some models​ share⁤ similar ⁢flow characteristics but differ in housing footprint or connector pinout, which will prevent direct substitution despite superficial similarity.

Replacement and⁢ installation require⁢ both electrical and hydraulic ⁣checks: verify the supply voltage printed on the pump, measure motor ‌winding continuity⁤ to rule ⁣out ‍an open rotor, clear any foreign ⁣debris from the pump ⁤chamberand confirm that ‌the impeller turns freely before power is applied. For installation, disconnect power, remove the access⁢ panel, ⁤note the pump orientation and hose routing, transfer‌ or replace gaskets and clampsand reconnect the wiring harness in the same pin order; after reassembly perform‍ a leak ⁤and ‌operational test​ by initiating a⁤ drain⁢ cycle. Practical examples ‍include using​ the original clamp type to preserve ⁣hose sealingor fitting a⁣ short adapter ⁢hose​ when the replacement ​outlet is offset; do not use mismatched gaskets⁣ or sealants that can ⁢distort​ the housing and ‌cause leaks or⁤ impeller ​rubbing.

  • Verify mechanical fit: flange dimensions, mounting holesand discharge orientation.
  • Verify electrical fit:‌ connector type, pinoutand nominal supply on⁢ the service label.
  • Pre-install tests: continuity‍ of motor windings, free impeller rotationand visual ⁤inspection for debris.
  • Post-install checks: leak ​test at hose‍ connections and⁤ operational drain-cycle⁢ verification.
Item Description
Service label Contains ​nominal ‌voltage​ and model ⁣cross-reference-use for final compatibility check.
Connector Confirm​ pin count and ⁢arrangement; identical connectors avoid⁤ rewiring or ⁤adapter harnesses.
Mounting Flange pattern and discharge orientation must match to prevent⁢ hose misalignment.
Installation checks Continuity test,impeller free-spin,gasket condition,and leak test after reassembly.

Q&A

What ⁣is the‌ 137108000 Frigidaire Water‌ Drain Pump and ‌Motor Assembly and what does‍ it do?

The⁣ 137108000 is a drain pump and⁤ motor assembly ​used on many ⁤Frigidaire dishwashers⁤ (and ‌some‌ other appliance models).‍ Its job is to ⁤remove wash⁤ and rinse water ‌from ‌the ⁢dishwasher tub by ‍driving an impeller‍ that pushes water out​ through the ​drain hose ‍and into the household drain. It combines the‌ electric ⁢motor and​ pump housing ⁣into a single serviceable unit.

What are the common symptoms that indicate the ⁢drain pump has failed?

Common symptoms include standing water in the tub after‍ a cycle,the dishwasher not advancing past the drain step,unusual loud grinding or humming⁣ noises during drain​ cycles,intermittent draining,or error codes ​related to draining on the control panel. ‍A humming noise with no water movement frequently enough indicates the ​motor is getting power but the impeller ​is ​jammed or the pump is seized.

How can ‍a technician or ‍homeowner ⁢test whether the pump motor is good?

First, disconnect power‌ to ‌the dishwasher. Visually inspect for ‌obstructions⁣ in ⁢the⁢ impeller housing and⁢ remove debris. With power still disconnected, use a multimeter to check ‍for ⁢continuity across‌ the pump motor terminals; an open circuit ‌indicates a failed motor.To verify‌ electrical‌ operation, restore‌ power ⁣and carefully measure the voltage ⁤at the pump terminals during ⁢a⁣ drain cycle (usually ~120 VAC in U.S.models) – only do this if you are comfortable⁣ working with live ⁣circuits. if the correct voltage​ is present but the motor does ‍not run, the motor/pump assembly is faulty.

can I replace the 137108000 myself and ​what tools/steps are ⁤involved?

Yes, a competent DIYer ‌can replace it. Basic steps: disconnect‍ power‌ at the⁤ breaker and‍ turn ‌off water supply,remove the lower access panel⁢ or toe kick,place towels to catch⁣ water,disconnect the ⁢drain⁣ hose(s) and any water lines,unplug the electrical connector(s) to‌ the⁢ pump,remove the mounting screws/clips and withdraw the old ⁤assembly,install the new assembly making sure gaskets/seals are seated,reconnect hoses and​ wiring,and test for leaks and proper operation. Typical tools: screwdriver set, ​pliers, bucket/towelsand a multimeter for checks. Follow the​ appliance service manual for⁤ model-specific​ steps and safety‍ precautions.

What‌ should I‍ check before replacing the pump to avoid needless replacement?

Check for‍ and remove foreign objects (glass, food, labels) in the pump or‍ filter area, clean the filter and sump,‍ verify the drain⁤ hose is not‍ kinked or cloggedand confirm the ⁤control board/door latch is ‌commanding a ⁣drain cycle. Also ‌test for​ voltage at the pump during drain; if‌ there is⁢ no ‌voltage,the issue might be the control board,wiring,or a ⁣float switch rather than the pump​ itself.

Is the 137108000 interchangeable with other part numbers or ‌aftermarket ‍pumps?

Some pumps are cross-referenced to other OEM or aftermarket ​part numbers ‌and might‌ potentially be physically interchangeable,‍ but ⁣fit, connector typeand hose ​locations ⁤can vary ​by model‍ year. Always confirm compatibility by⁢ checking your dishwasher’s⁢ model number against the parts list or the manufacturer’s⁢ cross-reference. Using an exact OEM⁤ part is the ​safest way to ensure correct fit and performance.

Why‍ is the pump making‍ a loud grinding or ⁤rattling noise and⁣ how​ do I fix it?

Loud ⁣noises are​ usually ⁢caused by debris (broken ​glass, silverware, labels) contacting the impeller, a ​damaged impelleror a ‌failing motor bearing. Start by removing and inspecting the⁣ pump area for foreign objects and ​clean the sump. ⁢If the ⁣impeller ​is chipped or the motor bearings are worn​ (grinding/rumbling),‍ the pump ​assembly should be replaced.

What ⁣maintenance can extend the ⁤life of the drain pump assembly?

Regularly clean the filter/sump area⁢ and inspect for stray items,avoid placing non-dishwasher-safe ⁢items in the⁣ dishwasher,check the ⁢drain ⁢hose for kinks or ⁣buildup,and occasionally run ​a​ rinse cycle with a‌ dishwasher-safe ⁣cleaner to remove grease and mineral deposits. Promptly address any‌ unusual noises or ⁤draining ‌issues to prevent motor overload and premature failure.

In Summary

The 137108000 ⁢Frigidaire Water Drain Pump and‍ Motor ⁣Assembly serves ⁢as a critical component in Frigidaire appliances by removing wastewater efficiently ⁤and⁣ reliably during ⁣operation. ⁤Proper ⁤function of this assembly⁣ ensures‍ complete cycle drainage, helps maintain appliance hygiene, reduces the risk ​of ​internal water accumulation and damageand contributes to optimal performance and energy use. As the pump ​directly⁣ affects‍ cycle completion‍ and prevents leaks ⁣or overflow, its⁤ condition⁣ has a direct impact‌ on ⁤appliance longevity and user satisfaction.

Accurate ‍diagnosis and timely replacement of a failing 137108000 ⁣assembly are essential to ​avoid secondary problems ⁤and restore reliable ​operation. Routine troubleshooting-such as checking hoses, filters, electrical‌ connectionsand diagnostics codes-helps distinguish​ pump failures ⁤from other issues.⁢ When testing ⁢indicates ⁤pump malfunction, replacing⁢ the part⁤ with⁤ the correct, ​compatible assembly and following manufacturer installation and ‌safety guidelines will minimize downtime‌ and further risk. Engaging qualified service personnel when needed ensures the work is done safely and⁢ in accordance with warranty or service requirements, providing the most ​cost‑effective outcome over the ‍appliance’s service life.


Professional Appliance Service

If your appliance requires professional diagnosis or repair, visit

Revolff Home Services
for expert appliance repair services.

For local appliance service information see

Dryer repair Henderson
.

Replacement parts for many appliance models can also be found at

Reliable-Parts-Hub
.

Recommended Products