316272000 Frigidaire Igniter and Orifice Holder is a combined⢠ignition⣠and gas āmetering⤠mounting component used in Frigidaire gas cooking appliances; it serves as the mechanical support ā¢and positioning feature that secures the igniter element (spark electrode or, in some designs, a hot surface igniter) and the gas⢠orifice (jet) in relation to the āburner head.
Inside an appliance āthe assembly interfacesā directly with the burner,theā gas valve/orifice train and the applianceā electrical control circuits. The holder locates ā¢and stabilizes the orifice to provide a consistent gas jet and maintains the correct spacing and alignment between theā igniter and āburner ports so āignition timing and āflame characteristics remainā predictable.It also provides electrical insulation and mechanical mounting ā£points for ā£the igniter ā¤wiring and contributes to sealing and āretention of the orifice against⣠the valve body; therefore it is part of both the fuel delivery andā ignition subsystems that must work together for safe, repeatable ignition and stable combustion.
In the article āthat follows, readers will find a technical ā¤overview of the part’s function and construction, guidance on⤠model compatibility ā£and naturalāgas vs. LP orifice considerations, common failure symptoms to recognize (suchā as, no ignition, repeated clicking, delayed ignitionā or abnormal flame), diagnosticā checkpoints to isolate igniter versus fuel delivery faultsand practical replacement considerations and safety precautions to observe when servicing or replacing the 316272000 assembly.
Table of Contents
- Functional Role ā¤and System Integration of the Igniter and Orifice Holder in Gas Burner ā¤Operation
- How the 316272000 Frigidaire igniter and Orifice Holder Operates Within the Burner Assembly and Gas Delivery Circuit
- diagnostic Indicators and Common Failure Symptoms of the Igniter/orifice Holder Assembly
- Replacement considerations, Seal and Torque Specificationsandā StepābyāStep Installation Procedures for the 316272000 Frigidaire Igniter and Orifice Holder
- Q&A
- In Retrospect
Functional role and System Integration of the āIgniter and Orifice Holder in gas Burner Operation
The 316272000 Frigidaire Igniter and Orifice Holder combines the ignitionā element āand the gas metering seat into a ā£single serviceable assembly that interfaces directly āwithā the burner manifold⤠and the appliance control system. The igniter provides the initial energy-either ā¢as ā¤a⤠high-voltage spark or⣠a hot-surface element depending on the appliance design-to initiate combustion, while⣠the⣠orifice holder positions and seals the replaceable orifice that determines volumetric gas flow toā the burner. proper function requires correct mechanical alignment so the spark or hot surfaceā is positioned relative to the burner portsā andā an orifice ā¤sized for the intended fuel type; incorrect orientation, a mismatched orificeor degraded ignition output will result in delayed ignition, sputteringor incomplete combustion.
- Electrical interface: mates to the range control/ignition moduleā and must present proper continuity or voltage waveform for reliable sparking or āheating.
- Gas āmetering: holds the orifice that⣠sets BTU⢠flow for Natural gas / āLP service and must match manifold ā¤pressure and appliance calibration.
- Mechanical fit: secures⤠to the manifold to maintain port alignment and provide a gas-tight seat around the orifice.
- Diagnostics: common ā£failure modes include open or high-resistance āigniter, loose mounting, ā¢or clogged/incorrect orifice.
In practical service, technicians should verify both electrical and pneumatic parameters when replacing the assembly: confirm ignition voltage or resistance, check that the orifice size corresponds āto the appliance conversion (natural vs LP)and inspect the mounting⢠flange and gasket for gas leaks.Such as, a range showing constant clicking with no flame often traces to a cracked igniter electrode or poor grounding at āthe orifice holder,ā whereas weak or yellow āflames usually indicate an undersized or obstructed orifice or incorrect gas pressure. Replacing the 316272000 ā¢Frigidaire Igniter and Orifice Holder with⢠an exact-fit āassembly and validating āmanifold pressure restores designed combustion characteristics and ensures safety interlocks and flame-sensing circuits operate asā intended.
| Item | Description |
|---|---|
| Ignition type | Spark or āhot-surface element; must match appliance control ā¤output |
| Orifice function | Positions replaceable orifice to regulate gas flow and BTU āoutput |
| Compatibility | designed for specific Frigidaire āmanifolds and model families; confirm part number and gasā type |
How the 316272000 Frigidaire Igniter and Orifice Holder Operates Within the Burner Assembly and Gas Delivery Circuit
The 316272000 Frigidaire Igniter and Orifice Holderā mounts directly at the burner head and performs two coordinated functions: it secures the gas orifice to the manifold and it locates the ignition element relative to the burner ports. by maintaining a sealed gas ā£passage and the correct electrode-to-port spacing, the⣠part⢠sets the initial flow characteristics and the ignition geometry needed for consistent lighting. This component is an OEM-fit item for specific Frigidaire ranges and must match the manifold thread,orifice diameter,and āmounting orientation of the appliance rather than being treated as a worldwideā replacement.
- primary ā¢functions: positions orifice, secures igniter, prevents flashback.
- Compatibility checks: manifold thread pitchorifice sizeand mounting flange alignment.
- Common failure symptoms: delayed ignition, ācontinuous clicking, yellow or sooty flame, gas odor.
- Field checks: electrode gap, visibleā cracks in insulatorand āleak testing⣠after reassembly.
| Item | Description |
|---|---|
| Function | Holds the orifice and ignition electrode in precise relation to the burner ports to control flow rate and spark position. |
| Installation note | Match orifice diameter and manifold thread; tighten retaining fasteners without deforming the seat and ā¢perform a soap-bubble leak check. |
In the gas delivery circuit, fuel⣠exits⤠the manifold, passes through the orifice held by the assemblyand is distributed to the burner ports where the igniter initiates ā¢combustion. The orifice diameter determines the mass flow for a given manifold pressure, while the āholder’s alignment and sealingā affect flow stability; āany carbon buildup, loose mountingor damaged ā¢insulation can alter flow or electrode gap āand cause ā¤hardā ignition or an unstable flame. For practical service, technicians should ā£verify the correct orifice size,⢠confirm the electrode gap (typically on the⢠order⤠of a⣠fewā millimeters for spark systems), inspect the holder for cracksā or corrosionand observe the ignition āsequence and flame pattern āafter āreassembly.
Diagnostic indicators and Common Failure Symptoms of the Igniter/Orifice Holder Assembly
The 316272000⤠Frigidaire Igniter andā Orifice Holder is⣠a combined āignition electrode and orifice-mounting component that positions the spark source relative to the burner nozzle while securing the gas āorifice in the correct axial alignment. Functionally, the assembly provides the mechanical interface (mounting tabs and orifice seating) and the electrical interface (insulated electrode āand wire ā¤connector) ā£required for repeatable ignition.ā Compatibility depends on matching the physical mounting pattern, connector typeand orifice size to the specific Frigidaire cooktop or range model; an incorrect orifice or misaligned electrode will alter combustion characteristics, increase ignition timeor create unstable flames. Technicians should consider electrode gap, ceramic insulator integrityorifice bore cleanlinessand harnessā continuityā when evaluating whether this assembly is the⣠appropriate ā¢replacement part for a given appliance.
Common diagnostic indicatorsā and failure symptoms can be grouped into electrical, mechanicaland combustion signs that point to a degraded igniter/orifice holder rather than upstream ācomponents ā¤such⢠as theā gas valve. Typical symptoms include:
- Delayed ignition or repeated clicking before a flame establishes (oftenā caused by weak spark or intermittent electrode contact).
- Continuous sparking after ignition ā£or failure to stop clicking (possible shortā to ground or ignition control issue).
- Weak,ā liftingor yellow-tipped flame⤠near the burner (clogged or eroded orifice reducing flow āor altering jet shape).
- Gas odor without ignition or slow light-off (misaligned or blocked orifice, damaged electrodeor insufficient spark āenergy).
- Visible cracks in theā ceramic insulator, corrosion onā the orificeor physical deformation of the holder (mechanical failure⣠affecting gap and āalignment).
Practical checks include a visual⤠inspection for damage, measuring electrode gap and continuity āwith a multimeterand verifying the orifice bore is free of debris.ā If the listed āsymptoms correspond with damagedā insulation, āeroded orifice edgesor inconsistent electrical readings, replacing the assembly with the correctly specified unit restores designed spark geometry and orifice positioning, improving ignition ā£reliability and flame stability.
| Item | Description |
|---|---|
| Compatibility | Matches specific Frigidaire mounting pattern and connector; confirm model compatibility before replacement |
| Common ā¤failure modes | Cracked ceramic, electrode wear, clogged/eroded orificeand harness/connector faults |
Replacement Considerations, Seal and Torque Specificationsand StepābyāStep Installation Procedures for the 316272000 Frigidaire Igniter and orifice Holder
The 316272000 āFrigidaire Igniter and Orifice Holder locates the gas āorifice and⢠positions the spark or hot-surface igniter relative to the burner port so a controlled, repeatable ignition can occur. This assembly āmust withstand thermal cycling, combustion byproducts and āthe electrical environment āof a range or oven; inspect the mating⣠faces for warping, carbon build-up or damaged threads before reuse. Verify compatibility with the appliance model and confirm the part ā£number; identical-looking holders can differ in orifice size, mounting hole pattern⢠or igniter orientation, which⣠affects flame shape and safety interlocks. Technicians ā¢should confirm the⤠correct spark gap and igniter alignment during replacement to maintain reliable ignition and consistent flame sensing behaviour.
- Disconnect electrical power and shut off the gas supply; āventilate the area and release any residual pressure per appliance service instructions.
- Remove burner components and access the orifice holder mounting screws; note the orientation of the igniter lead⤠and the orifice port for reassembly.
- Withdraw the assembly,clean ā£the manifold bore and orifice port,replace the flat gasket or Oāring with a gas-rated replacement,and inspect the orifice for obstruction or damage.
- Reinstall the new orifice holder,align the igniter ā¤so the tip is positioned as⤠specified by the appliance (typically a few millimetres from the port),tighten ā¤the mounting screws to the specified torque,restore ā¤gas and power,then perform ā£a pressure/leak test and functional ignition check.
| Item | Description |
|---|---|
| Mounting screw torque | 10-15 inĀ·lb (1.1-1.7⤠NĀ·m) – typical torque for the holder-to-manifold screws; use āa calibrated torque ā£driver. |
| Seal | replace with the OEM flat gasket or a gas-rated highātemperature Oāring; avoid general-purpose silicone on mating flange surfaces. |
| Igniter ā¤positioning | Tip clearance typically a few millimetres from the orifice; confirm against appliance service diagram for exact gap. |
| Fastener size | Commonly M4-M5 orā #8 screws for the holder mount; verify screw size before installation. |
Follow leak-testingā and functional verification procedures after installation: use a manometer or approved leak-detection fluid at the service valve and orifice connection, observe flame pattern and flame ā¤sensor⣠responseand log āthe results. For gas connector unions and pipe fittings, use the appliance manufacturer’s⣠specified torque or approved threadāsealant technique for gas service;⣠avoid over-torquing theā orificeā holder screws, which can deform the gasket surface and produce leaks or misalignment. Keep replacement parts and fasteners cleanand ādocument part numbers and torque⤠values for future maintenance records.
Q&A
What is the Frigidaire 316272000 igniter and orifice holder and what does it do?
The 316272000 assembly is an OEM replacement part for Frigidaire gas ranges/ovens that combines the igniter (the component that ālights the gas) and the orifice holder (the bracket that holds the gas orifice/jet and positions it⢠at the burnerā manifold). Together they ā¢deliver gas to theā burner ā£and provide the ignition source so ā¤the ā¤burner lights reliably.
How do I know if the 316272000 assembly is the correct part for my appliance?
Always verify compatibility by checking your stove/oven model number (usually on a tag behind the oven door,on the frame,or inside the storage drawer) and comparing itā to the part number cross-reference in the Frigidaire parts list. If you’re āunsure, enter your appliance model on the manufacturer website or consult an ā¤authorized parts distributor to confirm ā£that 316272000 is the correct āreplacement.
What symptoms indicate the igniter or orifice holder needs replacement?
Common signs āinclude: burner failsā to light or lights only intermittently;⢠delayed ignition with a strong smell of gas; weak or uneven flame; visible damage such as cracked or broken igniter, corrosionor a loose orifice holder; or the ā£igniter gets power (you hear/see⢠the control trying) but āthere is no spark or glow.⣠Any gas smell ā¤or repeated ignition failures indicate immediate attention.
Can I test the igniter to determine whether āit’s bad before replacing the 316272000 assembly?
Yes. First visually inspect for cracks, burnsor physical damage. Use a multimeter to check for continuity across the igniterā leads-an open circuit⣠indicatesā failure. Also verify that ā¢the control is sending voltage to the igniter when a burner is called for (use appropriate voltage testing procedures and safetyā precautions). If the igniter has continuity but receives voltage andā still doesn’t light,ā theā igniter is likely defective and should be replaced.
Is it difficult to install the 316272000? What safety steps should I take?
Installation difficulty is moderate and requires basic tools and comfort working with gas appliances. Safety steps: disconnect electrical power to theā appliance, turn off the gas supply, work in a well-ventilated area, āand avoid open flames. After installation, turn the gas back on and check all connections for leaks with aā soap-and-water solution. If you’re not comfortable with gas/electrical work, hire a qualified technician.
Can I āreplace āonly the igniter or only the āorifice holderor must Iā replace the entire 316272000 assembly?
That depends on your model and part availability. Some appliances⣠allow separate replacement of the igniter or the orifice holder; other designs sell⤠them as a single integrated kit (316272000). Check parts diagrams for your specific model. If the⣠integrated assembly is soldā as one piece, it’s usually recommended to āreplace the entireā unit to ensure correct alignment and safe operation.
Do I need a different orifice⢠whenā converting between natural gas and LP (propane)?
Yes. Natural gas and LP require different orifice sizes and sometimes different pressure regulators. If you convert fuel type, use theā correct orifice⤠jet for LP vs ā£natural gas as ā£specified by the manufacturer and follow conversion instructions in ā¤the appliance⢠manual.Improper orifice sizing can produce unsafe flame characteristics and must be handled by a qualifiedā technician if you are unsure.
How should I clean or maintain⤠the igniter and ā£orifice holder to prolong ā¢their life?
Keep the area around the burner and orifice free of food debris and grease. Do not use harsh abrasives orā detergents ā¤on ā£the igniter element-wipe gently with a soft, dryā cloth if⣠necessary. If the orifice is clogged, do not poke with hard objects; it’s safer to replace the orifice or assembly. Regularly inspect connections and burner alignment; perform a leak check after any maintenance that involves gas fittings.
In retrospect
The 316272000 Frigidaire Igniter and Orifice Holder ā£plays a key role in the ignition system āof compatibleā gas āappliances āby positioning the igniter andā regulating the gas āflow to the burner. Proper function of thisā assembly helps ensure reliable ignition, consistent flame characteristics, efficient combustionand reduced risk of delayed ā£ignition or gas buildup; when installed and maintained correctly, it contributes to both appliance performance and occupant safety.
Because ignition issues can stem from multiple causes, accurate diagnosis is ā£essential before replacement. When testing indicates āthe igniter and orifice holder are worn, damagedor out of specification, replacing the component with the correct 316272000 part restores intended operation and minimizes the chance of ārecurring problems. For safety and best results, diagnostics and replacement should be performed in accordance with the manufacturer’s⢠guidance or by a qualified service technician.
Professional Appliance Service
If your appliance requires professional diagnosis or repair, visit
Revolff Home Services
for expert appliance repair services.
For local appliance service information see
Dryer repair Henderson
.
Replacement parts for many appliance models can also be found at
Reliable-Parts-Hub
.