4387535 Whirlpool ⁣Refrigerator‍ compressor Relay ⁢Adn​ Overload Start⁢ kit ⁢is a combined start​ device ​and thermal protector designed for⁤ single‑phase refrigerator compressors. The ⁣kit ‌typically consists of a start relay (wich momentarily⁢ connects the compressor’s start winding ⁣or alters start⁤ circuit impedance⁣ to provide‍ initial torque) and an overload ‌protector​ (a thermal or current‑sensing device that ‌opens the compressor supply​ when operating temperature or current exceeds safe‌ limits).⁣ As a discrete service part it replaces factory original relay/overload assemblies ‍mounted on or near the hermetic compressor housing.

Inside the appliance the relay and overload ‌behave as an​ interface‌ between the refrigerator’s control system and the compressor motor. ⁢During a ​start ⁤sequence the relay provides ⁤the ⁢transient electrical⁤ condition ⁤necessary for the compressor’s motor to overcome static friction and reach‍ running speed;⁢ the overload sits in‍ series with⁤ the compressor supply to interrupt ​power ⁤if the motor draws excessive⁢ current⁢ or overheats. The​ assembly therefore interacts directly with⁢ the ⁣compressor’s start and ⁢run windings, the incoming mains and ⁢cabinet controls (thermostat or control board), ⁤and⁤ indirectly affects refrigerant circulation, evaporator defrost cycles ​and overall system pressures through its influence on compressor operation.

In‍ this article readers will find a technical explanation of ⁤how the 4387535 kit functions, guidance on ‌verifying compatibility with ‌specific compressor models‍ and electrical ratings, common failure symptoms to recognize (such as humming with no start, intermittent starts, rapid‌ cycling or excessive starting current), practical⁣ troubleshooting steps‌ using basic diagnostic ​toolsand ⁢replacement considerations such as‌ matching terminal configuration, current and temperature ⁣ratings, mounting method and ⁢safety precautions. The coverage is intended to‍ help technicians, engineers and​ appliance owners ​make⁤ informed decisions about diagnosis, ‌part selection and safe replacement⁢ practices without‌ prescribing specific marketing choices⁣ or exaggerated performance claims.

Table of contents

Function and Role of the Compressor ​Relay and overload Start ‍Kit ‌in the Refrigerator Refrigeration Cycle

The 4387535 Whirlpool Refrigerator Compressor Relay And Overload Start Kit combines the momentary starting relay and the‌ thermal overload ⁤protector that ⁢together manage compressor startup ‍and protect ⁣the ‍motor during ⁣the refrigeration cycle. The relay provides a ‍temporary high-torque current path ​to the compressor’s start⁣ winding ⁤(or engages an‌ external⁢ start device) only while the ‍motor accelerates; once the ​rotor ⁣reaches operating speed​ the relay opens⁤ or disengages,⁣ leaving the run ‍winding⁢ to maintain compressor operation. The overload is a ⁤temperature-​ or current-sensitive normally-closed protector mounted on ‍the‌ compressor shell that ⁤opens the circuit under sustained ‌overcurrent or excessive temperature, preventing winding damage and internally-locked-rotor failures. In ‍practical⁢ installations‍ the kit mounts on the ⁤compressor terminal block and must match the compressor terminal layout ‌and voltage rating to⁣ function correctly.

Behavioral and compatibility aspects⁤ dictate ⁢both ⁣diagnosis⁤ and replacement practice:⁣ a failed ⁢relay often produces rapid⁢ clicking,a persistent humming compressor that does not⁤ start,or repeated attempts to start ‍followed ‍by overload trips; a failed overload ⁣will​ interrupt run current and leave the‌ system non-operational⁣ until ⁣it cools or is replaced. Typical technician checks include measuring line voltage at compressor terminals,verifying continuity across ‌relay contacts during manual⁤ stimulation,and comparing terminal⁣ orientation ⁤to the replacement kit. Symptoms, installation notesand quick​ reference values are summarized below to aid ‌troubleshooting and part selection.

  • Common symptoms: ‍repeated clicking, compressor hum without rotation,‌ fridge warm while fan runs.
  • Diagnostic ⁤checks: line‍ voltage, continuity across overload,​ audible​ relay actuation during startup.
  • Installation ⁢tips: match terminal pattern‍ and voltage rating, ensure firm terminal connections, mount ⁣kit to compressor ​shell for accurate ⁣thermal ‍response.
Item Description
Function Relay provides startup⁢ current; ⁤overload protects against sustained‌ overcurrent/overtemperature.
Typical location Mounted on compressor terminal block/shell in close physical⁣ contact ​with compressor body.
Compatibility notes Must match ​compressor terminal ‌configuration and operating‌ voltage; verify OEM part cross-reference before replacing.

How the 4387535 Whirlpool Refrigerator Compressor Relay And Overload‌ Start Kit operates Within ⁢the Compressor Motor Circuit

The 4387535⁣ Whirlpool Refrigerator Compressor ⁢Relay And ‍Overload Start Kit combines a start‍ relay and‍ a thermal overload into a single​ replacement assembly⁢ that controls ​how the compressor ‌motor energizes and is⁣ protected. In operation, the relay provides a‌ timed​ or current-sensitive connection to the compressor’s ⁣start ⁣winding to produce the initial torque needed to turn the ⁣motor, then removes that connection once the motor reaches running speed.​ The⁢ thermal overload ⁤is wired in series‍ with ‌the compressor supply (typically the common led)⁤ and⁤ interrupts power if the compressor draws excessive current or the ‌motor temperature rises beyond⁣ safe limits.‌ This⁤ kit is intended for use​ on ‍three-terminal hermetic compressor motors where a discrete start device ⁢and an overload protector are‌ required for safe, reliable⁤ starting and ⁤protection ‍during⁣ stall ‍or overcurrent conditions.

During a⁣ normal ​start cycle the relay ⁣allows ​a‌ higher current or a‍ start-phase⁢ path ​for​ a brief interval; once ⁣the run speed ​and back‌ EMF reduce ⁤the need‍ for⁤ start winding current, the⁤ relay opens ⁢(or drops out) and the compressor continues on the⁣ run‍ winding only. The overload remains⁢ closed‌ while temperature and current⁢ are within limits and will open to de-energize the compressor if a stuck rotor,‌ locked loador ‌sustained overheating ‍occurs, ‍preventing further ‍damage. Technicians​ typically check ​for relay failure ‌by observing symptoms ‌such as ⁤repeated⁣ clicking,⁤ a humming ​compressor that ⁢will ‌not ⁤startor an overload that has tripped; bench tests include​ continuity and resistance checks across the three compressor terminals and verifying ⁤that the relay disengages after the motor comes up to ⁤speed. Practical replacement considerations include matching terminal layout and physical mounting​ to ensure correct electrical sequence and adequate thermal contact for‍ the overload ‍element.

  • Primary behaviors: provides momentary start energization; overload ⁢opens on⁣ overcurrent/overtemperature.
  • Compatibility: designed for three-terminal hermetic compressors; ensure terminal mapping⁣ matches the compressor block.
  • Common failure symptoms: non-starting compressor with hum, rapid cycling, ​or a visibly tripped overload.
item description
Relay function Connects start ⁢winding during ‍initial‍ spin-up, then​ disconnects once running speed‌ is reached.
Overload function Series thermal/current protector that opens to disconnect compressor‍ on sustained⁢ overload or overtemperature.
Typical ⁢terminals Common (C), Start (S), Run (R) – ⁤match to compressor terminal ⁢block.
Failure indicators clicking relay, ⁤humming/no-start compressor, ⁢or repeated trips of the overload

Common Failure Symptoms and Electrical/Mechanical ⁤Diagnostic Indicators for‌ Relay and Overload Assemblies

The relay⁢ and overload assembly controls the compressor’s start sequence ‌and ⁢protects the motor⁤ from overcurrent ⁤and overheating. The ​ 4387535 ‍Whirlpool Refrigerator Compressor​ Relay And Overload Start Kit replaces the start relay⁢ (or PTC/current-sensing element) and the thermal overload used on⁤ many‍ single‑phase hermetic compressor motors; a failing‍ relay⁤ or⁣ overload typically‌ produces audible and electrical symptoms rather⁣ than visible refrigerant-related faults. Common ​field ⁤symptoms ‌include a hard-starting compressor that ⁢hums but does not run,immediate tripping of the overload after ​a brief run,intermittent starting,or a compressor that will run‌ only when lightly tapped.⁢ Compatibility considerations​ include terminal layout, mounting type,​ and nominal voltage/current ratings-using ‌a physically similar part with ‍incorrect ⁣ratings can allow initial operation but cause premature failure or inadequate⁣ protection.

Diagnosing relay versus‌ overload faults requires both visual inspection and electrical measurements: the overload is normally a closed device ⁣that opens ​under excessive temperature or current, so an open circuit at ‍ambient temperature indicates a failed protector; the start​ relay (PTC or current relay) may show high​ resistance, a short to ⁣groundor loss ​of the low‑impedance start path. Practical diagnostic steps include measuring continuity between ‍common and ‍start terminals with the ‌compressor⁢ disconnected, checking resistance values⁢ against OEM​ specificationsand ​observing compressor behavior when a known-good start device is‍ temporarily substituted⁣ (performed only by qualified technicians with proper safety precautions). Mechanical indicators⁣ such ‌as melted plastic, burned⁤ contactsor a distorted housing frequently⁣ correlate with internal thermal or overcurrent‍ events⁢ and should ⁢prompt replacement ​rather ⁣than repair.

  • Compressor hums but ​does not start – likely⁢ open/failed start device or weak start winding.
  • Compressor starts then trips after short run – overload opening due⁤ to overcurrent‍ or high ‍running ‌temperature.
  • Intermittent starting/cycling⁣ – marginal relay/PTC performance or intermittent‌ thermal ​contact.
  • Visible damage ‍(charring,‍ melted housing) – ⁤replace instantly; often indicates thermal ⁤runaway or short.
Item Description
Humming/no-start Start relay failed to provide inrush path; bench⁣ test‌ or ⁢substitute start device⁣ confirms relay fault.
Immediate trip after start Overload ‍opens due ⁣to excessive ‌current or internal overheating; measure continuity cold and⁢ inspect compressor load.
Intermittent operation Intermittent contact or​ marginal PTC characteristic; evaluate resistance‌ stability and perform run/load observations.

Compatibility, Replacement Considerations, Installation Procedures and Troubleshooting ​Workflow

The⁢ 4387535 Whirlpool Refrigerator ⁣Compressor Relay And Overload Start Kit combines​ a start relay ‌and ‍thermal overload protector ⁣that work together to establish the starting current path for the compressor and⁤ to remove power if ⁣the motor overheats or ​draws an excessive current. Functionally, the relay momentarily connects the start winding to the supply to generate the necessary starting torque, while the overload⁤ opens under sustained overcurrent or high temperature ⁤to protect the compressor. Compatibility ⁤depends ⁢on the compressor’s⁤ electrical characteristics⁣ (rated‌ voltage, ⁣start and run winding resistanceand terminal arrangement) and the kit’s physical mounting and terminal configuration; technicians should confirm ⁤the refrigerator model,‍ compressor nameplate ratingsand the relay’s terminal layout before installing the​ kit. Check whether the⁣ original used‌ a ⁤PTC-type or mechanical relay and ensure the replacement matches the compressor’s voltage ‌and terminal​ design‌ to avoid misoperation ⁤or ‍mechanical stress on terminals and⁣ harnesses.

  • Disconnect power and document ‌terminal positions/photograph connections ​before removal.
  • Symptoms indicating relay/overload failure: repeated clicking,⁤ compressor hum without start, ⁢warm compressoror visible charring‍ on the relay body.
  • Quick bench checks: continuity across overload, proper continuity/transition ⁢of ‌relay terminals when energizedand comparison of start ​winding ⁢resistance⁢ to nameplate⁢ or service data.
Item Description
part 4387535⁢ Whirlpool ⁤Refrigerator Compressor Relay⁤ And Overload Start​ Kit
Compatibility Designed for common single-phase ‍refrigerators; verify ‌compressor nameplate ‌voltage and terminal orientation prior ‍to replacement
Technical reference Rated⁣ for typical household 120 VAC systems; consult compressor‍ nameplate‌ for​ start/run ⁣winding resistance and current limits

Installation⁣ and troubleshooting follow a structured workflow: isolate⁢ mains, remove the ​access panel, inspect the old relay/overload for ⁢thermal damage or carbon tracking,‍ and replace using the same terminal sequence and‍ mounting orientation ‍to preserve stress relief on the wiring. After replacement,measure‌ supply voltage at the compressor,verify continuity across the‍ overload with the⁣ unit⁢ de-energized,then restore power and​ observe starting behavior​ while⁢ measuring inrush current with a ‍clamp meter if available; a correct ⁣installation will result in a brief high inrush current during startup followed‍ by ​normal running current.⁢ If ⁣the new kit ‌does ⁢not correct the fault, proceed to verify compressor windings for short‌ or open circuits, check the start capacitor‌ (if‍ present) and control boardsand consider sealed-system ⁢faults-document findings and‌ escalate to sealed-system service if compressor windings test within specification but the unit still fails to ⁢start.

Q&A

What is the 4387535‍ Whirlpool Refrigerator Compressor Relay ‍and Overload Start Kit?

The ⁢4387535 kit is‌ a ⁣replacement​ start ⁣kit for certain whirlpool-brand ⁤refrigerators ‌that contains the compressor ⁢start relay and the thermal ⁢overload protector. The relay gives the compressor an extra starting boost⁤ and the overload⁤ protects the compressor motor from ​overheating ​or drawing ⁤excessive ⁣current. Together they help the‌ hermetic compressor start reliably⁣ and ‍protect it⁢ from damage.

What common symptoms indicate the ⁢relay/overload kit ⁤needs replacing?

Common symptoms include: the refrigerator ‌not ⁢cooling⁤ while ⁢the compressor either does not‍ run or only hums, a loud humming or clicking noise from the compressor area, the ‍compressor starting intermittently or only after long‌ delays, ⁤frequent tripping of the ⁤circuit ⁤breakeror a ⁣burnt electrical ⁢smell near ‌the relay. If the compressor‌ won’t start but gets warmor‌ the unit repeatedly starts and stops, the⁤ relay or overload is a‍ likely culprit.

How can I test the relay and overload before replacing⁤ them?

Always disconnect power⁣ first. Remove‍ the relay/overload⁢ from⁤ the compressor and test with a ⁣multimeter.⁤ The overload (a thermal protector)⁤ should show electrical continuity at room temperature; ⁣an‌ open ‍circuit indicates failure. For ​the ‍relay, ⁤check for continuity between the appropriate terminals⁢ per the part diagram – many relays‌ will show low resistance ⁣across start/run terminals or continuity through the ⁣start⁣ circuit. ⁢Also listen for a ⁤clicking ⁤sound during attempted ‍start (relay engaging). If you’re unsure interpreting results, consult​ a ​qualified appliance technician. Do ⁣not attempt ‍high-voltage bench testing unless trained.

Can I install ‌the ‍4387535 kit myself, ‌or do ​I need a technician?

If you⁢ are⁢ comfortable working safely with appliances and ‍basic hand tools, you can‌ replace the plug-in⁣ relay/overload yourself: unplug the refrigerator, access the ‍compressor (usually at the back behind a lower access panel), remove the old relay/overload ​from the compressor terminals and​ install the new unit, then restore power⁢ and verify⁢ operation. However, if the ⁤compressor ‌requires refrigerant​ work or the compressor itself is suspected to be failing, you should hire a licensed appliance or ‌refrigeration ⁤technician. Always disconnect power before servicing.

Is the 4387535 kit compatible with all Whirlpool refrigerators?

No-this kit is ⁤compatible only with⁣ refrigerators that ⁢use a conventional hermetic compressor with a plug-on relay/overload ⁣assembly. It is indeed not compatible with inverter or variable-speed​ compressors used in some modern​ models. Always check your⁣ refrigerator’s model‍ number and the parts diagram (or the OEM cross-reference) to confirm compatibility before purchasing.

Will ⁤replacing the relay/overload fix a compressor that‌ will‌ not start at all?

Sometimes yes: if the compressor is otherwise healthy but the⁢ start relay or‌ overload⁤ has ⁣failed, replacing ⁣them will restore starting⁢ function.However, if‌ the compressor has an internal mechanical failure​ (locked ⁢rotor, burned windings, loss of‍ refrigerantor internal short), replacing the relay/overload​ will not fix⁢ it. If the compressor ⁣still won’t run after installing a ​known-good relay/overload, the compressor ‍likely⁣ needs professional diagnosis or replacement.

What safety precautions should⁣ I take when ⁢replacing the relay/overload?

Unplug the refrigerator before doing any work. Work on​ a cool, dry surface with​ the appliance disconnected from mains power. Avoid shorting compressor terminals together.⁣ Do not attempt refrigerant- or compressor-specific ⁣repairs unless you are certified⁢ (refrigerant handling laws apply in many places). If you smell burning or see oil on the compressor shell, stop and consult⁤ a‍ technician-these can indicate more serious ⁣compressor damage.

Should I buy an OEM 4387535 ⁤kit or ⁤is an aftermarket version acceptable?

An OEM‌ (Whirlpool-branded) part guarantees fit ⁤and the ⁣correct electrical ⁤characteristics for the intended ⁣models. Many reputable aftermarket ‍kits also work fine ‍and can be less expensive,⁤ but quality and specifications vary. Buy from a trusted supplier,compare part numbers and connector types,and verify ⁢model compatibility. If unsure, using ⁢the OEM part eliminates uncertainty‍ about ⁢fit ​and function.

The Way Forward

The‌ 4387535 Whirlpool Refrigerator ⁣Compressor Relay and Overload Start Kit is a small but essential component that enables the compressor to start reliably and protects it⁣ from electrical ⁢faults‍ and​ overheating. By combining⁢ a start ⁤relay and an overload protector, the kit helps⁤ ensure consistent compressor​ operation, maintain proper cooling performance, ‌and reduce the risk of more extensive compressor damage‍ that can ‌lead⁢ to costly repairs‍ or premature appliance failure.

Accurate​ diagnosis and targeted replacement are critical​ when⁣ this kit is suspected ​to be the source of ⁢a refrigeration issue. Symptoms such as a humming compressor that fails ⁢to start, intermittent coolingor overheating can indicate a faulty⁣ relay ‌or ⁤overload device, ‌but ⁤similar ⁤symptoms may also stem ⁢from other ⁣system components. Confirming the⁣ problem⁤ through proper testing or professional evaluation minimizes needless parts⁤ replacement and‍ restores safe, efficient ⁣operation.

When replacement is required, using the‍ correct part and⁢ following manufacturer specifications or professional installation practices helps preserve system ‍reliability and extend the service⁢ life ‌of the refrigerator. Timely, informed action-whether by a qualified technician or ⁣a educated owner-supports consistent cooling performance and‌ helps avoid ‌more notable⁤ damage and expense down the line.


Professional Appliance Service

If your appliance requires professional diagnosis or repair, visit

Revolff Home Services
for expert appliance repair services.

For local appliance service information see

Dryer repair Henderson
.

Replacement parts for many appliance models can also be found at

Reliable-Parts-Hub
.

Recommended Products